Installation Into A Masonry Fireplace - Rinnai Sapphire Operating Information And Installation Instructions

Hide thumbs Also See for Sapphire:
Table of Contents

Advertisement

CLOSE OFF FIREPLACE WITH
FIREPROOF MATERIAL.
DO NOT INSTALL UNDER A LOW
WOODEN SHELF.
Brick Flues shall be completely sealed
from cavities and shall be free from
mortar droppings or any other debris.
In this type of installation the spigot
must have an extension added which is
to extend beyond overhead brickwork.
The extension shall be constructed so
that it prevents falling debris entering
the flue spigot.
The spigot extension shall not be extend-
ed so far into the chimney so as to cause
any obstruction to the discharge of flue
gas.
Minimum clearance from end of spigot
extension to any obstruction 75mm.
REMOVE DAMPER PIXIE/BAFFLE
Any damper plate or baffle which has
been installed in the chimney shall be
removed.
Fit flue cowl.
An approved cowl shall be fitted to the
chimney, with a minimum clearance of
200mm between top of chimney and the
lowest opening in the flue cowl.
PREPARATION OF FIREPLACE
Provide a firm, flat base for unit, fireplace
must be sealed, no holes or openings.
Seal all openings in back, base or sides
of fireplace.
A rough base or unsealed fireplace may
affect the performance of this heater.
FIT BACK SPACER AND WALL CLIPS:
See page 13 & 14.
CONNECT GAS and CHECK FOR
ESCAPES: Se e page 11 & 14.
TEST UNIT and I N S T R U C T
CUSTOMER: See page 16.
FIREPROOF MATERIAL
TO FILL IN FIREPLACE
FLUE OPENING
200mm
min.
APPRO
VED
COWL
75mm min.