Connecting air hose
1
007187
Slip the air socket of the air hose onto the air fitting on
the nailer. Be sure that the air socket locks firmly into
position when installed onto the air fitting. A hose
coupling must be installed on or near the tool in such a
way that the pressure reservoir will discharge at the
time the air supply coupling is disconnected.

OPERATION

To drive a nail, you may place the contact element
against the workpiece and pull the trigger.
014921
CAUTION:
WITH THE TRIGGER HELD IN A HALF-PULLED
POSITION, an unexpected nailing could occur, if contact
element is allowed to re-contact against the workpiece
or the other surface under the influence of recoil.
In order to avoid this unexpected nailing, perform as
follows;
A.
Do not place the contact element against the
workpiece with excessive force.
B. Pull the trigger fully and hold it on for 1-2 seconds
after nailing.
Direction of exhaust air
007189
2
1. Air fitting
2. Air socket
1. Exhaust cover
1
The direction of exhaust air
degrees of angle by turning the exhaust cover with a
hand.
Removing nails
CAUTION:
Do not use deformed nails or nail strip. Failure to
do so causes poor nail feeding.
WARNING:
Always disconnect the hose before removing nails.
Open the slide door and remove nails from the
magazine.
014922
With the slide door kept open, open the door and take
out nails.
Removing the contact top allows nails to be easily taken
out. When re-installing the contact top, insert the
prorusion of the contact top into the notch in the contact
arm.
1
014923
1
014924
6
can be changed 360
1. Latch
1. Contact top
2. Contact arm
2