Eaton T800R-00500 Instruction Manual
Eaton T800R-00500 Instruction Manual

Eaton T800R-00500 Instruction Manual

Power-sure 800
Table of Contents

Advertisement

Power-Sure 800
Instruction manual—single-phase power conditioners

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T800R-00500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Eaton T800R-00500

  • Page 1 Power-Sure 800 Instruction manual—single-phase power conditioners...
  • Page 2: Table Of Contents

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 3 2-2 Input volts and amps specifications 8–25 kVA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 4: Safety And Preparations

    High leakage current. Earth connection is essential likely to cause harmful interference, in which case before connecting supply. the user will be required to correct the interference at the users own expense . Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 5: Symbol Usage

    A potentially hazardous situation which, if not avoided, In no event will Eaton be responsible to the purchaser or may result in minor or moderate injury or in property user in contract, in tort (including negligence), strict liability, damage incidents.
  • Page 6: Serial Numbers

    Power-Sure T800P serial number: _________________________ Power-Sure T800F serial number: _________________________ Additional serial numbers: _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 7: Section 1: Introduction

    . guide to assist the user with any communication and configuration connections . Startup service is offered by Eaton . Do not allow unqualified personnel to handle, install, or operate Power-Sure 800 power conditioners . 1.2: Receiving Before accepting shipment from the freight carrier, inspect 1.5: General description...
  • Page 8: Electrical Specifications

    Power output ● ● Single-phase, 100% duty kVA/kW, for linear and Operating temperature ● ● non-linear loads . Ambient range –20 to +40 ºC . +200% applies to T800P/T800F models only . Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 9: Power-Sure T800R/T800P/T800F Cabinet Dimensions

    Range 2: 208/240/480 . Input and output voltage is field configurable; units will ship from the factory configured as follows: Range 1—120 V (input/output); Range 2—240 V (input/output) . Range 3: 120/208/240 . Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 10: Cabinet Standard Dimensions For 500-850 Va, Power-Sure T800R Models

    (1) 6-50R 208/240 (1) L14-30R 120/240 (1) 14-20R 120/240 Example: T800R-100002B2Y consists of 2 (2) 5-15R receptacles and 2 (1) L14-30R receptacles. Figure 1-2: Cabinet standard dimensions for 500–850 VA, Power-Sure T800R models Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 11: Cabinet Standard Dimensions For 5-15 Kva, Power-Sure T800R Models

    Introduction Figure 1-3 Cabinet standard dimensions for 1–3.5 kVA, Power-Sure T800R models Figure 1-4: Cabinet standard dimensions for 5–15 kVA, Power-Sure T800R models Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 12: Cabinet Dimensions T800P Wall-/Panel-Mounted Unit, 500-1000 Va

    Introduction Figure 1-5: Cabinet dimensions T800P wall-/panel-mounted unit, 500–1000 VA Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 13: Cabinet Dimensions T800P Wall-/Panel-Mounted Unit, 1500-3000 Va

    Introduction Figure 1-6: Cabinet dimensions T800P wall-/panel-mounted unit, 1500–3000 VA Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 14: Cabinet Dimensions T800P Wall-/Panel-Mounted Unit, 5000-10,000 Va

    Introduction Figure 1-7: Cabinet dimensions T800P wall-/panel-mounted unit, 5000–10,000 VA Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 15: Cabinet Dimensions T800F Floor-Mounted Unit, 5000-10,000 Va

    Introduction Figure 1-8: Cabinet dimensions T800F floor-mounted unit, 5000–10,000 VA Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 16: Cabinet Dimensions T800F Floor-Mounted Unit, 15,000-25,000 Va

    Introduction Figure 1-9: Cabinet dimensions T800F floor-mounted unit, 15,000–25,000 VA Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 17: Section 2: Installation

    T800F with high inrush currents will cause the output voltage to fall below usable levels if they exceed 150% of the unit’s current rating . If high inrush currents are expected, the Power-Sure T800R/T800P/T800F must be oversized Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 18: Wiring Diagrams

    2.3: Wiring diagrams Figure 2-1: Wiring diagram for 500–850 VA T800R (120 Vac input and output, 60 Hz) Figure 2-2: Wiring diagram for 1–2.5 kVA T800R (120 Vac input and output, 60 Hz) Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 19 Note: 3 .5 kVA 120 Vac load currents (X1–N or X2–N) should not exceed 50% of the unit’s rated power @ 120 Vac . Neither duplex receptacle should be loaded more than 14 .5 A . Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 20: Wiring Diagram For 5–7 .5 Kva T800R (208/240 Vac Input And 120/208/240 Vac Output, 60 Hz)

    Installation Figure 2-5: Wiring diagram for 5–7.5 kVA T800R (208/240 Vac input and 120/208/240 Vac output, 60 Hz) Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 21: Wiring Diagram 10–15 Kva T800R Models

    Installation Figure 2-6: Wiring diagram 10–15 kVA T800R models Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 22: Wiring Diagram 500 Va–5 Kva T800P/T800F Models

    Maximum wire size: 10 AWG ● ● Recommended torque: 15 lb in ● ● 3000 VA #10 stud ● ● Maximum wire size: 6 AWG ● ● Recommended torque: 20 lb in ● ● Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 23: Wiring Diagram 8–25 Kva T800P/T800F Models

    ● ● Recommended torque: 45–50 lb in ● ● Note: Full kVA ratings may be used at 120 Vac on secondary windings with exception of 20 kVA and 25 kVA units . Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 24: Input Volts And Amps Specifications 500 Va-5 Kva

    Maximum wire size: 10 AWG Maximum wire size: 6 AWG ● ● ● ●●●● Recommended torque: 15 lb in Recommended torque: 20 lb in ● ● ● ●●●● Figure 2-9: Hardwiring for 500 VA–5 kVA units Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 25: Input Volts And Amps Specifications 8-25 Kva

    208V X1–X2 ●● ●●●●● 480V H1–H4 240V X1–X3 ●● ●●●●● 120V X3–N ● ●●●●● Terminals Wire range: 10–1/0 AWG ●● Recommended torque: 45–50 lb in ●● Figure 2-10: Hardwiring for 8–25 kVA units Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 26: Section 3: Maintenance

    . particles . A slight tug should be used to test if there are any Replace the fan in this situation . loose electrical connections . Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 27: Notes

    _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ Instruction manual—single-phase power conditioners IM01002005E September 2015 Eaton.com...
  • Page 28 . From ground- tomorrow’s needs today . breaking products to turnkey Follow the charge with Eaton . design and engineering services, Visit eaton .com/electrical . critical industries around the globe count on Eaton .