DEK 265 horizon Engineering Specification page 29

Table of Contents

Advertisement

Specification
Chapter Issue 1 May 00
Inspection
Maximum Number of Sites
Maximum Site Size
Automatic Learn
Stencil Inspection
Aperture Blockage
Stencil Smear
Board Inspection
Paste on Pad
Bridging
Paste Alignment
Predictions
Paste Volume
Programmable Inspection
Rate
General Inspection
Parameters
Programmable Action on
Alarm
Engineering Specification
ENGINEERING SPECIFICATION
Specification
500 sites
4 mm by 4 mm
Single Site
Rows
Columns
QFP
BGA
BGA Frame
Accuracy
(Within)
±6%
±0.1mm²
±5%
±0.05mm
±0.01mm
±6%
All sites inspected every cycle
Selected sites inspected every cycle
Inspection of sites every n cycles
Individual site limits
Individual site naming option
Each inspection site can be given a unique name to make it
traceable
Programmable warning and alarm levels for individual sites
Reprint after low paste detection
Under screen clean after blockage or smear detection
MACHINE OPTIONS
Repeatability
±5%
±0.05mm²
±5%
±0/02mm
±0/01mm
±5%
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents