Pfaff Powerline 2545 Adjustment Manual page 50

Hide thumbs Also See for Powerline 2545:
Table of Contents

Advertisement

2
Circuit diagrams
.04
Reference list for the Circuit diagrams 91-191 519-95
A1
A1
A2
A14
A15
A16
A20/1
A20/2
B30
B41
H1
R1
M1
Q1
S1.1
S1
S2
S3
S4
S5
S6
S7
S8
S26
S27
S28
S29
X0
X1
X2
X2.1
X2.2
50
PFAFF 2545 and 2546 PLUS
Steuergerät P74 ED-L
Controller P74 ED-L
Control panel (PicoTop)
Sewing head recognition (OTE)
Oil sensor (2C-Bus)
Keyboard (2C-Bus)
Bobbin thread monitor 1 (optional)
Bobbin thread monitor 2 (optional)
Slider monitoring (optional)
Oil sensor (2C-Bus)
Sewing lamp
Potentiometer for reduced speed
during stroke adjustment
Sewing motor
Main switch
Pedal speed control unit
Key 1 depending on parameter
other function
Key 2 depending on parameter
other function
Key 3 depending on parameter
other function
Key 4 depending on parameter
other function
Key 5 depending on parameter
other function
Key 6 depending on parameter
other function
Key 7 depending on parameter
other function
Key 8 Emergency off
Start inhibitor
Stroke adjustment
Speed limitation from 9mm
stitch length on
Centre guide
RS232 interface (PC)
Sewing motor
Incremental transmitter
Incremental transmitter
Synchronizer PD 6
Circuit diagrams
X3
Speed control unit
X4
PicoTop control panel
X5
Input/output plug
X7
Light barrier plug & bobbin thread
monitor (optional)
XA14
A14 Sewing head recognition (OTE)
XA15.1
A15 Oil sensor (2C-Bus)
XA15.2
A15 Oil sensor (2C-Bus) >
A16 Keyboard (2C-Bus)
XA20
A20 Bobbin thread monitor (optional)
XR1
R1 Potentiometer for reduced speed
during stroke adjustment
XS26
Start inhibitor
XS27
Stroke control
XS28
Speed limitation from 9mm
stitch length on
XS29
Centre guide
XY3
Y3 Thread clamp (-909/..)
XY4
Y4 Presser foot lift (-910/..)
XY5
Y5 Backtacking device (-911/..)
XY6
Y6 Stroke adjustment (-918/26)
XY8
Y8 Thread tension release
XY9
Y9 Thread trimmer (-900/..)
XY12
Y12 2nd stitch length quick
adjustment (-918/29)
XY13
Y13 Trim stitch
XY14
Y14 Thread tension control
XY15
Y15 Hook cleaning A20 Bobbin
thread monitor (-926/..)
Y3
Thread clamp (-909/..)
Y4
Presser foot lift (-910/..)
Y5
Backtacking device (-911/..)
Y6
Stroke adjustment (-918/26)
Y8
Thread tension release
Y9
-900/.. Thread trimmer
Y12
2nd stitch length (-918/29)
Y13
Trim stitch
Y14
Thread tension control
Y15
Hook cleaning A20 Bobbin thread
monitor (-926/..) optional
Y16
Centre guide unit (only on the 2546)
or -900/82

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerline 2546

Table of Contents