Adjusting
1
Needle postition in sewing direction
.07 .04
● Unscrew the needle plate and bottom transporter..
● Insert a 100/100 mm thick needle.
● Unscrew setting gauge 1 (Order No. 61-111 689-07).
● Adjust needle bar 2 (screw 3) in accordance with the rule.
● Unscrew the setting gauge again.
● Reassemble the bottom transporter.
36
Rule
At stitch length setting "0", the needle in sewing direction should pierce the middle of the
setting gauge hole 1.
1
Fig. 1 - 28
3