Adjustment
1
Preliminary adjustment of the needle height
.05.08
● Without turning it, re-position needle bar 1 (screw 2) in accordance with the
14
Requirement
When the needle bar is positioned at t.d.c. (balance wheel position 0°), the clearance
between the needle point and the needle plate should be 22 mm.
2
Fig. 1 - 08
requirement.
Make sure that needle bar 1 and foot 3 do not collide.
1
3
1