Download Print this page

Panasonic LC2H preset Specifications page 4

Timers/time switches/counters/hour meters
Hide thumbs Also See for LC2H preset:

Advertisement

LC2H
2. PC board mounting type
Type
Item
Input method
No. digits
Rated operation voltage
Allowable operation voltage range
Current consumption
Max. counting speed
Min. input signal width
(ON: OFF = 1:1)
Input method
Count
input
Input impedance
Residual voltage
Min. input signal width
Input method
Reset
input
Input impedance
Residual power
Break down voltage (initial)
Insulation resistance (initial)
3. Common
Type
Item
Functional
Vibration resistance
Destructive
Functional
Shock resistance
Destructive
Operation temperature
Storage temperature
Ambient humidity
Applicable standard
Safety standard
(EMI)EN61000-6-4
Radiation interference electric field strength
Noise terminal voltage
(EMS)EN61000-6-2
Static discharge immunity
EMC
RF electromagnetic field immunity
EFT/B immunity
Conductivity noise immunity
Power frequency magnetic field immunity
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Max. 30 µA (max. 250 µA during reset input)
2 kHz
0.25 ms
Non-voltage input using contacts or open collector connection
Non-voltage input using contacts or open collector connection
Between charged and uncharged parts: 1,000 V AC for 1 minute.
Min. 100 MΩ (measured at 500 V DC) Measurement location same as for break down voltage.
Panel mounting/PC board mounting types
10 to 55 Hz (1 cycle/min.), single amplitude: 0.15 mm
10 to 55 Hz (1 cycle/min.), single amplitude: 0.375 mm
Min. 98 m/s
2
(4 times on 3 axes)
Min. 294 m/s
(5 times on 3 axes)
2
–10 to +55°C
+14 to +131°F
(without frost or dew)
–25 to +65°C
–13 to +149°F
(without frost or dew)
35 to 85% RH (non-condensing)
EN61010-1
PC board mounting type
Non DC voltage input
8 digits
3 V DC
2.7 to 3.3 V DC
When shorted: Max. 10 kΩ
When open: Max. 750 kΩ
Max. 0.5 V
10 ms
When shorted: Max. 10 kΩ
When open: Max. 750 kΩ
Max. 0.5 V
.006 inch
(10 min. on 3 axes)
.015 inch
(1 hr. on 3 axes)
Pollution Degree 2/Overvoltage Category III
EN55011 Group1 ClassA
EN55011 Group1 ClassA
EN61000-4-2
4 kV contact
8 kV air
EN61000-4-3
10 V/m AM modulation (80 MHz to 1 GHz)
10 V/m pulse modulation (895 MHz to 905 MHz)
EN61000-4-4
2 kV (power supply line)
EN61000-4-6
10 V/m AM modulation (0.15 MHz to 80 MHz)
EN61000-4-8
30 A/m (50 Hz)
30 Hz
16.7 ms

Advertisement