LC2H
Part names
1. Front reset key
This key resets the count value. It does
not work when the lock switch is ON.
2. Mode key
Use to switch between each mode.
3. Setting key
Used to set digits of preset values or set
each mode.
4. Set key
Use to set preset values or to switch
between modes.
5. Lock switch
Disable the operation of the front panel
reset key and the mode key. With the lock
switch on,
is displayed for about
two seconds when the reset key or mode
switch is operated.
6. Count speed switch
Use this switch to switch the count speed
between 30 Hz and 5 kHz.
Dimensions
• External dimensions
54.4
2.142
10.4
44
.409
1.732
22
.866
7
.276
• Panel cut out dimensions
The standard panel cut out is shown below.
Use the mounting bracket (ATH3803) and the rubber gasket (ATH3804).
(Only installation frame type)
60 min.
2.362 min.
45
1.772
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
RESET
MODE
1
2
5
Count speed switch
6
Notes: 1. Make the switch setting before installing to panel.
2. Please turn the power off if you change the setting of the count speed switch when the power is on. The
setting will become valid when the power is turned back on.
44.8
1.764
5
48
.197
1.890
COUNTER
24
.945
RESET
MODE
SET
LC2H
+0.5
0
+.020
0
+0.5
22.2
0
+.020
.874
0
COUNTER
SET
LC2H
3
4
6
(Terminal block side)
Lock switch
(unit display 1)
(Terminal block side)
(unit display 2)
When installing the one-touch installation type model, make sure
that the installation spring does not pinch the rubber gasket.
To prevent the installation spring
from pinching the rubber gasket:
1. Set the rubber gasket on both
ends of the installation spring
(left and right).
2. Confirm that the installation
spring is not pinching the rubber
gasket, and then insert and fix the
installation spring in place from the
rear of the timer unit.
• When installing repeatedly (sealed installation)
(Only installation frame type)
+0.5
22.2
0
+.020
.874
0
Notes: 1. Suitable installation panel thickness is 1 to 4.5 mm
2. Waterproofing will be lost when installing repeatedly (sealed installation).
5
❇: Default setting when shipped.
OFF❇
(LCD side)
ON
5kHz
(LCD side)
30Hz❇
mm
General tolerance: ±1.0
A
+1.0
A=(48×n-2.5)
0
+.039
A=(1.890×n-.098)
0
0.39 to 0.177
inch.
inch
±.039