Specifications
Item
Rated operating voltage
Rated power consumption
Rated control capacity
Input mode
Max. counting speed
Counting input
Reset input
Rating
Input signal
Output mode
Display method
Digit
Memory
Contact arrangement
Electrical life (contact)
Allowable operating voltage range
Electrical
Break down voltage (Initial value)
Insulation resistance (Initial value)
Functional vibration resistance
Destructive vibration resistance
Mechanical
Functional shock resistance
Destructive shock resistance
Operation temperature
Operating
Storage temperature
conditions
Ambient humidity
Protective construction
* The factory default preset value is set to 1000000.
Applicable standard
(EMI)EN61000-6-4
Radiation interference electric field strength
Noise terminal voltage
(EMS)EN61000-6-2
Static discharge immunity
EMC
RF electromagnetic field immunity
EFT/B immunity
Conductivity noise immunity
Power frequency magnetic field immunity
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Addition/Subtraction (selectable by front switch)
30 Hz/5 kHz (selectable by slide switch on side)
Min. input signal width: 16.7 ms at 30 Hz/0.1 ms at 5 kHz,
ON time : OFF time = 1 : 1
Min. input signal width: Min. 30 ms
• Non-voltage input using contacts or open-collector connection
• Input impedance; when shorted: Max. 1 kΩ, when open: Min. 100 kΩ
• Residual voltage: Max. 2 V
• Maintain output/hold count • Maintain output/over count
• One shot/over count • One shot/recount
(Selectable by front switch)
(Switch between red and green for backlight, and between lit and flashing for count up.)
–9999999 to 99999999 (–7 digits to +8 digits)
(0 to 99999999 for preset value)
EEP-ROM (Overwriting times: 10
1 Form A (Open collector)
10
operations (at rated control voltage)
7
85 to 110% of rated operating voltage
Between input and output: 1,500 V AC, for 1 min.
Between input and output: 100 MΩ (at 500 V DC)
10 to 55 Hz (1 cycle/min), Single amplitude: 0.15 mm (10 min. on 3 axes)
10 to 55 Hz (1 cycle/min), Single amplitude: 0.375 mm (1 hr. on 3 axes)
Min. 98 m/s
Min. 294 m/s
–10 to 55°C
+14 to +131°F
–25 to +65°C
–13 to +149°F
30 to 85% RH (at 25°C 77°F, non-condensing)
IP66 (front panel with mounting bracket and rubber gasket)
EN55011 Group1 ClassA
EN55011 Group1 ClassA
EN61000-4-2
4 kV contact
8 kV air
EN61000-4-3
10 V/m AM modulation (80 MHz to 1 GHz)
10 V/m pulse modulation (895 MHz to 905 MHz)
EN61000-4-4
2 kV (power supply line)
1 kV (signal line)
EN61000-4-6
10 V/m AM modulation (0.15 MHz to 80 MHz)
EN61000-4-8
30 A/m (50 Hz)
Descriptions
24 V DC
Max. 1.5 W
100 mA 30 V DC
7-segment LCD
operations or more)
5
2
(4 times on 3 axes)
(5 times on 3 axes)
2
(without frost or dew)
(without frost or dew)
LC2H