Shutting down the heating system

With frost protection monitoring

Select heating program " " for frost pro-
tection monitoring (standby mode).
Press the following keys:
1.
for settings; "
2. OK to confirm; "
3. OK to confirm; "
4.
until " " flashes.
5. OK to confirm; frost protection mon-
itoring is activated.
■ No central heating.
■ No DHW heating.
■ Frost protection for the boiler and the
DHW cylinder is enabled.
Note
The circulation pumps are briefly started
every 24 hours to prevent them from
seizing up.

Without frost protection monitoring (shutdown)

1. Switch the ON/OFF switch " "
OFF.
2. Close the gas shut-off valve.
Note
Ask your heating contractor to
explain the positioning and handling
of these components.
Terminating heating program " "
Select another heating program.
Press the following keys:
" flashes.
1.
" flashes.
2. OK to confirm; "
" flashes.
3. OK to confirm; " " flashes.
4.
5. OK to confirm; the selected heating
3. Isolate the heating system from its
main power supply, e.g. at a separate
MCB/fuse or a mains isolator.
4. Where outside temperatures of
below 3 °C are anticipated, please
take suitable measures to protect the
heating system against frost. If nec-
essary, contact your heating contrac-
tor.
Start-up/shutdown
for settings; "
" flashes.
" flashes.
until "
" flashes: The rooms
are heated and DHW is provi-
ded.
or
until " " flashes: DHW is
heated but central heating is not
active.
program is activated.