Disassembly Of Outdoor Unit - IVT 12PHR-N Service Manual

Split type air to air heat pump
Hide thumbs Also See for 12PHR-N:
Table of Contents

Advertisement

12PHR-N
55)Four fixed screws of the vertical direction louver stand assembly
removed.
56)Driving motor of the vertical direction louver stand assembly is
removed. (2 screws)
57)The bearing holder is removed. (1 screw)

[2] DISASSEMBLY OF OUTDOOR UNIT

1) The fixed screw of control box cover is removed and control
box cover is removed.
12PHR-N_S530612PHRN.indd 8
58)The cross flow fan fixation screw is loosened.
59)The two screws for the fan motor cover fixation are removed.
60)The cross flow fan is pulled out at the left of the unit and it removes.
61)Fan motor is removed.
2) The 2 screws on the right-hand side of top plate ass'y is
removed.