IVT AY-XP12JHR-N Service Manual

Split type room air conditioners

Advertisement

TopPage
[1]
SPECIFICATION.................................... . ....... 1-1
[2]
EXTERNAL DIMENSION....................... . ....... 1-2
[3]
WIRING DIAGRAM ................................ . ....... 1-3
[4]
ELECTRICAL PARTS ............................ . ....... 1-3
[1]
BLOCK DIAGRAMS............................... . ....... 2-1
[2]
[3]
FUNCTION............................................. . ....... 2-9
[1]
OPERATIONS........................................ . ....... 3-1
[2]
THERMISTOR ERROR ......................... . ....... 3-3
[3]
ACTERISTICS ....................................... . ....... 3-5
[4]
UNIT INDEPENDENTLY........................ . ....... 3-6
SERVICE MANUAL
ROOM AIR CONDITIONERS
MODELS
INDOOR UNIT
AY-XP12JHR-N
In the interests of user-safety (Required by safety regulations in some
countries) the set should be restored to its original condition and only
parts identical to those specified should be used.
CONTENTS
........ 2-3
SPLIT TYPE
[5]
[6]
OD .................................................................3-8
[7]
[8]
TROUBLESHOOTING GUIDE ....................3-13
[1]
FLOW FOW REFRIGERANT ........................4-1
[2]
STANDARD CONDITION ..............................4-1
[3]
PRESSURE IN 3-WAY VALVE ......................4-1
[4]
PERFORMANCE CURVES...........................4-2
[1]
DISASSEMBLY OF INDOOR UNIT...............5-1
[2]
This document has been published to be used for
after sales service only.
The contents are subject to change without notice.
AYXP12JHRN
OUTDOOR UNIT
AE-X12JR-N
........3-6

Advertisement

Table of Contents
loading

Summary of Contents for IVT AY-XP12JHR-N

  • Page 1: Table Of Contents

    ROOM AIR CONDITIONERS MODELS INDOOR UNIT OUTDOOR UNIT AY-XP12JHR-N AE-X12JR-N In the interests of user-safety (Required by safety regulations in some countries) the set should be restored to its original condition and only parts identical to those specified should be used.
  • Page 2: Chapter 1. Specification

    AYXP12JHRN AYXP12JHRN Service Manual CHAPTER 1. SPECIFICATION [1] SPECIFICATION 1. AY-XP12JHR-N – AE-X12JR-N MODEL INDOOR UNIT OUTDOOR UNIT ITEMS AY-XP12JHR-N AE-X12JR-N Rated cooling capacity (Min– Max.) 3.5 (0.9 - 4.0) Rated heating capacity (Min–Max.) 4.6 (0.9 - 6.5) Moisture removal (at cooling)
  • Page 3: External Dimension

    AYXP12JHRN [2] EXTERNAL DIMENSION 1. Indoor unit Unit 18.5 INVERTER AIR CONDITIONER 22.0 2. Outdoor unit 37.5 167.5 1 – 2...
  • Page 4: Wiring Diagram

    AYXP12JHRN [3] WIRING DIAGRAM 1. Indoor unit 2. Outdoor unit [4] ELECTRICAL PARTS 1. Indoor unit DESCRIPTION MODEL REMARKS Indoor fan motor MLB395 DC Motor Indoor fan motor capacitor – – Transformer – – FUSE1 – QFS-GA078JBZZ (250V, 3.15A) 2. Outdoor Unit DESCRIPTION MODEL REMARKS...
  • Page 5: Chapter 2. Explamation Of Circuit And Op- Eration Block Diagrams

    AYXP12JHRN AYXP12JHRN Service Manual CHAPTER 2. EXPLAMATION OF CIRCUIT AND OPERATION [1] BLOCK DIAGRAMS 1. Indoor unit Rectification circuit DC power supply circuit AC power 3.15A Fuse Fan motor PWM control circuit Indoor fan motor Rotation pulse input circuit Fan motor pulse detect AC clock circuit Remote controller signal reception circuit Wireless remote control operation...
  • Page 6 AYXP12JHRN 2. Outdoor unit AC clock circuit protection Pulse amplitube modulation circuit IGBT protection Unit-unit wiring (AC power Power supply circuit Smoothing Power factor Filter circuit converter circuit circuit and serial signals) CPU oscillator circuit 3.15A DC overvoltage detection circuit protection Outdoor fan drive circuit Outdoor fan...
  • Page 7: Microcomputer Control System

    AYXP12JHRN [2] MICROCOMPUTER CONTROL SYSTEM 1. Indoor unit 1.1. Electronic control circuit diagram 2 – 3...
  • Page 8 AYXP12JHRN 1.2. Display circuit diagram 2 – 4...
  • Page 9 AYXP12JHRN 1.3. Printed wiring board For JHR-N model main PWB From cluster unit From fan motor From horizontal louver motor To vertical louver motor(left) To vertical louver motor(right) From sensor PWB From pipe thermistor (relay connector) For JHR-N model sensor PWB To main PWB 2 –...
  • Page 10 AYXP12JHRN For JHR-N model connection PWB From hang From panel From panel From display From display From panel From panel From hang motor left motor left SW left PWB(black) PWB(yellow) SW right motor right motor right To main PWB To main PWB To main PWB To main PWB For JHR-N model display PWB...
  • Page 11 AYXP12JHRN 2. Outdoor unit 2.1. Electronic control circuit diagram 2 – 7...
  • Page 12 AYXP12JHRN 2.2. Printed wiring board To Terminal Board To Terminal Board To Control Box (N)(Blue) (2) (Red) To Terminal Board (Green/Yellow) (1) (Brown) From 4 Way Valve From Expansion Valve From Thermistor From Terminal Board To Reactor (Gray) From Fan Motor From Compressor (R) To Reactor...
  • Page 13: Function

    AYXP12JHRN [3] FUNCTION 1. Function 1.1. Restart control 1.5. Indoor unit overheat prevention control Once the compressor stops operating, it will not restart for 180 sec- During heating operation, if the temperature of the indoor unit heat onds to protect the compressor. exchanger exceeds the indoor unit heat exchanger overheat preven- tion temperature (about 45 to 54°C) which is determined by the operat- Therefore, if the operating compressor is shut down from the remote...
  • Page 14 AYXP12JHRN 1.9. Peak control 1.14. Power ON start If the current flowing in the air conditioner exceeds the peak control If a jumper cable is inserted in the location marked with HAJP on the current the operation frequency is decreased until the current value indoor unit control printed circuit board (control PCB), connecting the drops below the peak control current regardless of the frequency con- power cord to an AC outlet starts the air conditioner in either cooling or...
  • Page 15 AYXP12JHRN 1.17. Adjusting the air flow direction 1.17.2 Horizontal air flow direction 1.17.1 Vertical air flow direction Press the HORIZONTAL AIR FLOW but- ton to set the desired air flow direction Press the VERTICAL AIR FLOW button to set the desired air flow direction. AUTO mode AUTO obliquely downward...
  • Page 16 AYXP12JHRN 1.18. Difference of operation in Auto and Manual modes In the Auto mode, the temperature setting is automatically determined based on the outside air temperature. In addition, the air conditioner operation differs from the operation in the Manual mode as explained below. 1.18.1 Difference relating to set temperature Auto mode Manual mode...
  • Page 17 AYXP12JHRN 2. Explanation of cluster circuit The cluster unit generates cluster ions, which are circulated throughout the room by the air flow created by the blower fan (indoor unit fan motor) in the air conditioner unit. 1) When microcomputer output turns "H," the IC13 output changes to "Lo," turning ON the SSR1 and applying 100 V to the cluster unit for the gener- ation of cluster ions (positive and negative ions).
  • Page 18 AYXP12JHRN 3.2. High power factor control circuit This circuit brings the operating current waveform closer to the waveform of commercial power supply voltage to maintain a high power factor. Because of the capacitor input, when the PAM circuit is OFF, the phase of the current waveform deviates from the voltage waveform as shown below. To prevent this deviation, a current is supplied during the periods indicated by "O"...
  • Page 19 AYXP12JHRN 3.3.1 Details of troubleshooting procedure for PAM 1) PAM shutdown due to error 1) When the DC voltage detection circuit sends a signal exceeding the specified voltage to the microcomputer DC voltage of 400 V or higher (detection circuit input voltage of about 8.4 V or higher) [IC8 pin (4)] –...
  • Page 20 AYXP12JHRN 4. Explanation of IPM drive circuit The IPM for compressor drive is made by Mitsubishi Electric. The power supply for the IPM drive and the shunt resistance for overcurrent detection, are provided outside the IPM. 4.1. IPM drive power supply circuit The power supply for the upper-phase IGBT (HU, HV, HW) drive employs a bootstrap system, and provides power to the upper-phase IC.
  • Page 21 AYXP12JHRN 4.1.2 DC overcurrent detection circuit When a current of about 25 A or higher flows through the shunt resistance (R49) on the control printed circuit board (PCB), the voltage at this resis- tance is input to IPM CIN pin (15). Then, the gate voltage of the lower-phase IGBT (LU, LV, LW) inside the IPM turns OFF to cut off the overcurrent. At the same time, an L output of more then 20μs.
  • Page 22 AYXP12JHRN 5. 120° energizing control (digital position detection control) This control system detects the digital position detection signal and adjusts the rate of acceleration/deceleration accordingly. The motor's induced voltage waveform is input to the comparator in the form of PWM-switched pulse waveform, and a position detection signal is generated as a reference voltage equaling 1/2 of 280 VDC.
  • Page 23: Chapter 3. Function And Operation Of Pro- Tective Procedures Protection Device Functions And Operations

    AYXP12JHRN AYXP12JHRN Service Manual CHAPTER 3. FUNCTION AND OPERATION OF PROTECTIVE PROCEDURES [1] PROTECTION DEVICE FUNCTIONS AND OPERATIONS Function Operation Self-diagnosis result display Description Detection period Reset condition Indoor Indoor Outdoor unit unit unit error display Operation OFF or ON ✩2 Indoor unit fan lock Operation stops if there is no When indoor unit fan...
  • Page 24 AYXP12JHRN Function Operation Self-diagnosis result display Description Detection period Reset condition Indoor Indoor Outdoor unit unit unit error display Operation OFF or ON Yes ✩1 AC overcurrent Operating frequency lowers if out- When compressor is error door AC current exceeds peak in operation control current value.
  • Page 25: Air Conditioner Operation In Thermistor Error

    AYXP12JHRN Function Operation Self-diagnosis result display Description Detection period Reset condition Indoor Indoor Outdoor unit unit unit error display Operation OFF or ON Yes ✩3 26 Compressor rota- Compressor stops if there is no Compressor operat- tion error (at 120° input of position detection signal ing at 120°...
  • Page 26 AYXP12JHRN 2. Outdoor unit Item Mode Control opera- When resis- Short-circuit When resis- Open-circuit tion tance is low tance is high (temperature (temperature judged higher judged lower than actual) than actual) Compressor Cooling Expansion valve Compressor Compressor high Layer short-cir- Outdoor unit ther- chamber ther- Dehumidifying...
  • Page 27: Thermistor Temperature Characteristics

    AYXP12JHRN [3] THERMISTOR TEMPERATURE CHARACTERISTICS 1. Indoor unit thermistor temperature characteristics Figure 1 Temperature properties of indoor thermistors Room temperature Thermistor Signal Color thermistor TH1 (CN10 1 - 3 ) Room temperature Yellow Heat exchange Heat exchange Orange thermistor TH2 (CN11 1 - 2 ) To measure the resistance, first remove the soldering as shown at right.
  • Page 28: How To Operate The Outdoor Unit Independently

    AYXP12JHRN [4] HOW TO OPERATE THE OUTDOOR UNIT INDEPENDENTLY 1. Cooling in 40 Hz fixed mode To operate the outdoor unit independently, short-circuit the sections indicated by arrows in the diagram below with an adapter, and apply 220-240 VAC between (1) and (N) on the terminal board of the outdoor unit. This allows the outdoor unit to be operated in cooling mode independently. (Do not operate the outdoor unit in this condition for an extended period of time.) Short-circuit negative terminal of capacitor (C33) - and jumper...
  • Page 29 AYXP12JHRN Main cause Inspection method Normal value/condition Remedy Dew condensation on light receiv- Check for water and rust. Signal should be received within Take moisture-proof measure for ing unit. range specified in manual. lead wire outlet of light receiving section. 5.
  • Page 30: Malfunction (Parts) Check Meth

    AYXP12JHRN [6] MALFUNCTION (PARTS) CHECK METHOD 1. Procedure for determining defective outdoor unit IPM/compressor The following flow chart shows a procedure for locating the cause of a malfunction when the compressor does not start up and a DC overcurrent indi- cation error occurs.
  • Page 31 AYXP12JHRN 2. Procedure for determining defective expansion valve Measure resistance in expansion valve coil. Normal resistance between red terminal of expansion valve lead wire and each terminal: about 46 (at 20 (red) Checker Insert checker shown at left into connector (CN12) on control PWB, and operate air conditioner.
  • Page 32: Outdoor Unit Check Method

    AYXP12JHRN 5. IPM check method Turn off the power, let the large capacity electrolytic capacitor (C10) discharge completely, and dismount the IPM. Then, using a tester, check leak current between C and E. When using a digital tester, the (+) and (-) tester lead wires in the table must be reversed. Needle-type tester Normal resistance value Needle-type tester...
  • Page 33 AYXP12JHRN Item Check method Normal value/condition Remedy IPM circuit check Check that 3 lamps (load) light. Each voltage should be normal. Replace control PWB. Check position detection voltage (+15 All 3 lamps (load) should light with V, 5 V) on control PWB. same intensity.
  • Page 34 AYXP12JHRN 3. Caution in checking printed circuit boards (PWB) 3.1. Non-insulated control circuit The GND terminals of the low-voltage circuits (control circuits for microcomputer and thermistors and drive circuits for expansion valve and relays) on the control printed circuit board (PWB) are connected to the compressor drive power supply (320-VDC negative terminal). Therefore, exercise utmost caution to prevent electric shock.
  • Page 35: Troubleshooting Guide

    AYXP12JHRN [8] TROUBLESHOOTING GUIDE 1. Self-Diagnosis Function and Display Mode To call out the content of the self-diagnosis memory, hold down the emergency operation button for more than 5 seconds when the indoor unit is not operating. • The number of indications displayed by the LEDs on the outdoor unit differs from that for the 2001 cooling unit models (for detailed display of mal- function information).
  • Page 36 AYXP12JHRN Status of Indication Malfunction Content of diagnosis Inspection location/method Remedy indoor/ by LED1 No. dis- outdoor on out- played on units door unit main unit display sec- tion *1 Main Sub- Main category Sub-category cate- cate- gory gory Indoor/ 2 times Cycle tempera- Compressor high-...
  • Page 37 AYXP12JHRN Status of Indication Malfunction Content of diagnosis Inspection location/method Remedy indoor/ by LED1 No. dis- outdoor on out- played on units door unit main unit display sec- tion *1 Main Sub- Main category Sub-category cate- cate- gory gory Indoor/ 6 times Outdoor unit DC DC over current (1) IPM continuity check...
  • Page 38 AYXP12JHRN Status of Indication Malfunction Content of diagnosis Inspection location/method Remedy indoor/ by LED1 No. dis- outdoor on out- played on units door unit main unit display sec- tion *1 Main Sub- Main category Sub-category cate- cate- gory gory Indoor/ EEPROM error EEPROM (outdoor) (1) Replace the outdoor...
  • Page 39 AYXP12JHRN Status of Indication Malfunction Content of diagnosis Inspection location/method Remedy indoor/ by LED1 No. dis- outdoor on out- played on units door unit main unit display sec- tion *1 Main Sub- Main category Sub-category cate- cate- gory gory Indoor Wires between Serial open-circuit (1) Check the wires between...
  • Page 40 AYXP12JHRN Malfunction indications due to erroneous wiring during air conditioner installation Inter-unit wiring error mode Symptom Malfunction diagnosis display "18-1" Indoor Outdoor unit unit Malfunction diagnosis display None (Displays "18-0" when malfunction code is called out.) Indoor Outdoor unit unit Malfunction diagnosis display None (Displays "18-0"...
  • Page 41: Chapter 4. Refrigeration Cycle

    Relative Humidity (%) Dry-bulb Temp. (°C) Relative Humidity (%) Cooling Heating – * REFRIGERANT PIPE LENGTH 5m [3] TEMPERATURE AT EACH PART AND PRESSURE IN 3-WAY VALVE Model AY-XP12JHR-N NO. Condition Cooling Heating Temp. on (°C) Temp. on (°C) Temp. on (°C)
  • Page 42: Performance Curves

    NOTE 1) Indoor fan speed: Hi 2) Vertical adjustment louver "45°”, Horizontal adjustment louver "front" 3) Indoor air temp. : Cooling 27°C, Heating 20°C 4) Power source : 230V, 50Hz 1. AY-XP12JHR-N 1.2. At Heating 1.1. At Cooling 1100 1000 Outside air temp.( C)
  • Page 43: Chapter 5. Disassembling Procedure

    AYXP12JHRN AYXP12JHRN Service Manual CHAPTER 5. DISASSEMBLING PROCEDURE If, in carrying out repairs and modifications, the work requires the use of arc- and flame-producing apparatus, such as welding, brazing and soldering equipment, this work shall only be started after the rooms have been thoroughly ventilated. While the work is being carried out, the mechanical venti- lation, if any, shall be kept in constant operation and all windows and doors kept open.
  • Page 44 AYXP12JHRN 7) Remove the connector cover. (use the (-) screwdriver). 11)The tapes that is the fixation of the lead wire is peeled off. 8) All of the nine connectors are removed. 12)The panel base is drawn out forward. (both sides) 9) The hook three places of the part interior of front panel on are removed.
  • Page 45 AYXP12JHRN 15)The panel mechanism assembly is removed. (2 screws) 19)The display printed boad is removed. (Hook three places) 16)The display assembly is removed. (right and left two hooks place) 20)The panel mechanism cover is removed. (3 screws) 17)The cover of the display printed boad is removed. 21)The screw that is the fixation of the panel motor is removed, and is turned to the left and it is removed.
  • Page 46 AYXP12JHRN 23)The panel motor is removed. (2 screws) 27)The reception cover is removed. 28)The fixing band of the sub.printed boad assembly is cut. 24)The mechanism case is removed. (Hook one place) 29)The sub.printed boad assembly is removed. (2 screws) 25)The limit switch is removed. 30)Five connectors are removed from sub.
  • Page 47 AYXP12JHRN 31)The sub.printed boad cover is removed. (Hook two places) 35)The P.W.B. box cover is removed. 36)The fixing band in the P.W.B.assembly is cut. (4 parts) 32)The sub.printed boad is removed. (Hook two places) 37)The connectors in nine places are removed. 33)A fixed screw for P.W.B.
  • Page 48 AYXP12JHRN 39)The plasmacluster assembly is removed. (2 screws) 43)Six screws for the fixation of the air filter cleaning mechanism assembly is removed. 40)The plasmacluster assembly is pulled forward, and detached. 44)Air filter cleaning mechanism assembly is pulled forward and removed. 45)The limit switch cover is removed.
  • Page 49 AYXP12JHRN 47)The wire connector of the limit switch is removed. 51)The earth cable is removed. (1 earth screw ) 52)The P.W.B.assembly is drawn out forward. 48)The thermally sensitive resistor holder is removed. (Hook two places) 49)The relay printed bord holder removed. (2 screws) 53)The Terminal cover of the Terminal stand assembly is removed.
  • Page 50 AYXP12JHRN 55)The dew cover is removed. (The slide is done right and remove. ) 59)The drain pan is detached. 56)Two screws of cover L are removed. 60)Four fixed screws of the vertical direction louver stand assembly removed. 61)Driving motor of the vertical direction louver stand assembly is removed.
  • Page 51 AYXP12JHRN 63)The cross flow fan fixation screw is loosened. 64)The two screws for the fan motor cover fixation are removed. 65)The cross flow fan is pulled out at the left of the unit and it removes. 66)Fan motor is removed. 5 –...
  • Page 52: Disassembly Of Outdoor Unit

    AYXP12JHRN [2] DISASSEMBLY OF OUTDOOR UNIT 4) The screw on the right-hand side of front panel is removed 1) The fixed screw of control box cover is removed and control box cover is removed. 5) The screw on the right-hand side of front panel is removed 2) The 2 screws on the right-hand side of top plate ass’y is removed.
  • Page 53 AYXP12JHRN 8) The 2 screws on the right-hand side of side cover L is removed. 12)A bulkhead plate fixed 2 screws is removed. 9) The 7 screws of the side cover L and side cover R back is removed. 13)The compressor covers 1, 2 removed. 10)The connectors in the control box BOX and reactor is removed.
  • Page 54 AYXP12JHRN 15)A lead wire, a thermistor, and a cover gasket are removed. 19)The fixed 2 screws of a motor angle is removed. – Disassembly of Heater(CHET-A025JBKZ) Unit 1) Cut the band fixing the bi-metal thermostat. 2) Powercord for bi-metal thermostat. 16)The compressor cover is removed.
  • Page 55: Parts Guide

    ROOM AIR CONDITIONERS MODELS INDOOR UNIT OUTDOOR UNIT AY-XP12JHR-N AE-X12JR-N In the interests of user-safety (Required by safety regulations in some countries) the set should be restored to its original condition and only parts identical to those specified should be used.
  • Page 56 AYXP12JHRN [1] INDOOR UNIT PARTS 3-67 3-15 3-65 3-66 3-27 3-44 3-68 3-64 10-6 3-17 3-18 3-14 3-71 3-62 3-16 3-19 3-17 3-10 3-12 3-20 3-39 3-70 3-69 3-21 3-10 3-16 3-12 2-5A-5 3-39 2-5B-5 2-19 3-41 3-22 3-38 10-1 3-74 3-23 3-37...
  • Page 57 AYXP12JHRN PRICE PART PARTS CODE DESCRIPTION RANK MARK RANK [1] INDOOR UNIT PARTS FAN MOTOR SUB ASS'Y CMOT-A515JBKZ CONTROL BOARD UNIT DSGY-C542JBKZ THERMISTOR K RH-HXA113JBZZ LOUVER MOTOR RMOT-A174JBZZ LOUVER MOTOR VR RMOT-A179JBZZ LOUVER MOTOR VL RMOT-A176JBZZ 1-10 TERMINAL QTANZA054JBZZ 1-12 PLASUMACLUSTER UNIT CKITTA125AKKZ 1-17...
  • Page 58 AYXP12JHRN PARTS CODE P R I C E N E W P A R T DESCRIPTION RANK MARK RANK [1] INDOOR UNIT PARTS FIXING BAND LBND-A046JBE0 5-10 INSULATOR PFPFPD646JBEZ LEAD WIRE (for PC unit) QW-VZF947JBZZ MOUNTING ANGLE ASS'Y DPLT-A083JBKZ PIPE GAUGE PPLTNA118JBWZ 8-14 CGID-A047JBKZ...
  • Page 59 AYXP12JHRN PRICE PART PARTS CODE DESCRIPTION RANK MARK RANK [2] Panel opening and shutting mechanism R Assembly 2-15 PANEL MECHANISM R ASS'Y CBOX-A053JBKZ HOOK LHLD-A943JBFB LPIN-A009JBEZ GEAR-C MARMPA067JBMA CAM R MCAMPA010JBFZ GEAR 24 NGER-A040JBEZ GEAR 35 NGER-A041JBEZ HOOK ARM NSFT-A047JBFZ CASE RC PCAS-A076JBFA 2-10...
  • Page 60 AYXP12JHRN [3] Panel opening and shutting mechanism L Assembly PRICE PART PARTS CODE DESCRIPTION RANK MARK RANK [3] Panel opening and shutting mechanism L Assembly 2-35 PANEL MECHANISM L ASS'Y CBOX-A054JBKZ 2-21 HOOK LHLD-A943JBFB 2-23 PiIN LPIN-A009JBEZ 2-24 GEAR-C MARMPA067JBMA 2-26 MCAMPA012JBFZ 2-27...
  • Page 61 AYXP12JHRN [4] ACCESSORY PARTS 7-11 7-19 7-14 7-15 7-16 7-18 PRICE PART PARTS CODE DESCRIPTION RANK MARK RANK [4] ACCESSORY PARTS BUTTERY UBATUA027JBE0 SCREWS KIT FFZK-A247JBKZ 7-11 REMOTE CONTROLER CRMC-A768JBEZ 7-14 SPUIT USPT-A003CDEZ 7-15 LHLD-A998JBKZ COVER (for Cabele) 7-16 TINS-B168JBRZ INSTALLATION MANUAL 7-18 TINSEA569JBRZ...
  • Page 62 AYXP12JHRN [6] INDOOR PACKING PARTS PRICE PART PARTS CODE DESCRIPTION RANK MARK RANK [6] INDOOR PACKING PARTS PACKING CASE SPAKCC558JBEZ PAD R SPADBA448JBEZ SPADBA449JBEZ PAD L SPADBA462JBEZ CABI PAD SSAKAA106JBEZ CASE SPAKCJ944YDEZ...
  • Page 63 AYXP12JHRN [7] OUTDOOR UNIT PARTS 2-48-1 2-17 2-34 2-46-2 2-57 2-46-1 2-48-2 2-26 2-7-1 2-7-4 2-7-2 2-46-3 2-22 2-25 2-7-5 2-39-5 2-39-3 2-31 2-33 2-39-4 2-37 2-7-3 2-20 2-7-6 1-2-6 2-56 2-19 1-2-7 3-12 2-18 2-47-1 2-45 1-10 2-10 2-39 2-24 2-39-7 2-38...
  • Page 64 AYXP12JHRN PRICE PART PARTS CODE DESCRIPTION RANK MARK RANK [7] OUTDOOR UNIT PARTS FAN MOTER CMOTLB078JBEZ CONTROL BOARD UNIT DSGY-C541JBKZ 1-2-6 RH-IXA856JBZZ 1-2-7 DIODE BRIDGE VHDD25XB60+-F REACTOR RCILZA027JBZZ THERMISTOR RTHM-A022JBE0 TERMINAL BOARD QTANZA053JBZZ WIRE FW-VZA070JBKZ 1-10 FERRITE CORE RFIL-A126JBZZ 1-11 RH-HXA029JBZZ THERMISTOR ASS'Y 1-12...
  • Page 65 AYXP12JHRN PARTS CODE P R I C E N E W P A R T DESCRIPTION RANK MARK RANK [7] OUTDOOR UNIT PARTS 3-14 COMPRESSOR CUSHION GLEG-A099JBE0 3-15 SPECIAL NUT LX-NZA313JBEZ 3-17 PROTECTOR SPRING MSPR-A046JBE0 3-18 TERMINAL COVER PCOV-A833JBEZ 3-19 TERMINAL GASKET PSEL-A142JBEZ 3-20...
  • Page 66 AYXP12JHRN INDEX PRICE PART PRICE PART PARTS CODE PARTS CODE RANK MARK RANK RANK MARK RANK LHLD-A991JBFA 1-8-27 [ C ] LHLD-A995JBFZ 1-8-22 CBOX-A053JBKZ 2-2-15 LHLD-A998JBKZ 4-7-15 CBOX-A054JBKZ 3-2-35 LPIN-A009JBEZ 2-2-3 CCAB-A408JBKZ 7-2-2 " 3-2-23 CCHS-A931JBTA 7-3-1 LPIN-A010JBEZ 1-3-61 CCIL-A142JBKZ 7-3-8 LPLT-A058JBPZ 1-3-36...
  • Page 67 AYXP12JHRN PRICE PART PRICE PART PARTS CODE PARTS CODE RANK MARK RANK RANK MARK RANK PFTA-A090JBFA 7-2-7-2 RMOT-A164JBZZ 2-2-13 PFTA-A124JBFB 1-3-70 RMOT-A167JBZZ 3-2-38 PFTA-A125JBFB 1-3-62 RMOT-A172JBZZ 2-2-14 PGID-A166JBFA 1-3-40 RMOT-A173JBZZ 3-2-39 PGID-A167JBFA 1-8-28 RMOT-A174JBZZ 1-1-6 PGID-A168JBFA 1-8-29 RMOT-A176JBZZ 1-1-8 PGID-A169JBFA 1-8-30 RMOT-A179JBZZ 1-1-7...
  • Page 68 © COPYRIGHT XXXX BYSHARP CORPORATION ALL RIGHTS RESERVED. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of the publisher.

This manual is also suitable for:

Ae-x12jr-n

Table of Contents