12PHR-N
39)Air filter cleaning mechanism assembly is pulled forward and
removed.
40)The limit switch cover is removed.
41)The limit switch is removed. (Hook one place)
42)The wire connector of the limit switch is removed.
12PHR-N_S530612PHRN.indd 6
43)The thermally sensitive resistor holder is removed.
(Hook two places)
44)The relay printed bord holder removed. (2 screws)
45)P.W.B. assmbly is removed. (2 screws)
46)The earth cable is removed. (1 earth screw )
5-6