Warranty And Repairs; Temperature Test, Transport And Storage Information - ReSound PH13 User Manual

Custom hearing instruments
Table of Contents

Advertisement

technical Data (ITCs and ITEs)
HeaRIng InStRument moDeL
AL940, AL740, AL540, AL440, AL940-D, AL740-D, AL540-D, AL440-D
AL940-W. AL940-DW, AL740-W. AL740-DW, AL540-W. AL540-DW,
AL440-W, AL440-DW
AL940-P, AL740-P, AL540-P, AL440-P, AL940-DP, AL740-DP,
AL540- DP, AL440-DP, AL-940-PW, AL940-DPW, AL-740-PW,
AL740-DPW, AL-540-PW, AL540-DPW, AL-440-PW, AL440-DPW
AL950, AL750, AL550, AL450, AL950-D, AL750-D, AL550-D, AL450-D,
AL950-W, AL750-W, AL550-W, AL450-W, AL950-DW, AL750-DW,
AL550-DW, AL450-DW
AL950-P, AL750-P, AL550-P, AL440-P, AL950-DP, AL750-DP,
AL550- DP, AL450-DP, AL950-PW, AL750-PW, AL550-PW, AL450-PW,
AL950-DPW, AL750-DPW, AL550-DPW, AL450-DPW
VO950, VO750, VO550, VO950-D, VO750-D, VO550-D
VO950-W, VO750-W, VO550-W, VO950-DW, VO750-DW, VO550-DW
VO950-P, VO750-P, VO550-P, VO950-DP, VO750-DP, VO550-DP
VO950-PW, VO750-PW, VO550-PW, VO950-DPW, VO750-DPW, VO550-DPW
48

Warranty and repairs

ReSound provides a warranty on hearing instruments in the event of defects in workmanship or materials,
maxImum output
as described in applicable warranty documentation. In its service policy, ReSound pledges to secure func-
(2ccCoupler / IEC 60118-7
tionality at least equivalent to the original hearing instrument. As a signatory to the United Nations Global
and ANSI S3.22-2013)
Compact initiative, ReSound is committed to doing this in line with environment-friendly best practices.
Hearing instruments therefore, at ReSound's discretion, may be replaced by new products or products
manufactured from new or serviceable used parts, or repaired using new or refurbished replacement
117dB SPL (typical)
parts. The warranty period of hearing instruments is designated on your warranty card, which is provided
by your hearing care professional.
129dB SPL (typical)
For hearing instruments that require service, please contact your hearing care professional for assistance.
ReSound hearing instruments that malfunction must be repaired by a qualified technician. Do not attempt
to open the case of hearing instruments, as this will invalidate the warranty
117dB SPL (typical)

temperature test, transport and storage information

GN ReSound Hearing Instruments are subjected to various tests in temperature and damp heating cycling
between -25 C and +70C according to internal and industry standards. During transport or storage, the
129dB SPL (typical)
temperature should not exceed the limit values of -20C to 60C and relative humidity of 90% RH, non con-
densing (for limited time). The air pressure between 500 and 1100 hPa is appropriate.
118dB SPL (typical)
118dB SPL (typical)
130dB SPL (typical)
130dB SPL (typical)
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ph312Bo312Bo13

Table of Contents