ReSound Ziga BTE ZG80-VI User Manual

ReSound Ziga BTE ZG80-VI User Manual

Hide thumbs Also See for Ziga BTE ZG80-VI:

Advertisement

Quick Links

User GUide
resound Ziga
TM
BTe ZG80-Vi,
ZG80-dVi

Advertisement

Table of Contents
loading

Summary of Contents for ReSound Ziga BTE ZG80-VI

  • Page 1 User GUide resound Ziga BTe ZG80-Vi, ZG80-dVi...
  • Page 2: Table Of Contents

    Contents Page Your new digital ReSound Ziga hearing instruments will enable you Illustration of the hearing instrument......4 to hear sounds that you may not have heard in years because of your Adjusting to a world of new sounds .
  • Page 3 Your ReSound Ziga Hearing Instrument 8. Left/Right indicator (Right=Red, Left=Blue) 9. Battery lock 1. Programme Selector 10. Model . Battery Compartment & On/Off Switch 11. Manufacturer . Sound Outlet 4. 1 Microphone Sound Inlet .  Microphone Sound Inlet 6. Volume Control...
  • Page 4: Adjusting To A World Of New Sounds

    Adjusting to a World of New sounds How to adjust If you are inexperienced with hearing instruments it is advisable to: New sounds 1. Use your hearing instruments every day. A hearing loss is typically acquired gradually over many years. You may have become accustomed to an everyday life with fewer sounds, which .
  • Page 5: How To Use The Hearing Instrument

    How to Use the Hearing instrument inserting the instrument (with earmould) 1. Hold the earmould between your thumb and On/Off Function index finger and position its sound outlet in 1. When the battery compartment is fully closed, the instrument is your ear canal.
  • Page 6: Removing The Hearing Instrument

    removing the Hearing instrument Volume Control When using the instrument you can increase the volume by turning the To remove the hearing instrument, simply pull the tube outward with volume control up, and reduce volume by turning it down. your thumb and forefinger. Consult your hearing care professional if you have difficulties removing the hearing instrument.
  • Page 7: Programme Selector

    Programme selector Your Programme environments: (to be completed together your hearing care professional): You can have up to four different programmes on your hearing instru- ment. The selection of programmes can be changed by your hearing Programme Description of when to use care professional.
  • Page 8: Stand-By Function

    stand-by Function When using the telecoil programme, the receiver of the telephone should be held as shown in the drawing. You may need to move the In stand-by mode, the hearing instrument will not process sound or handset around slightly to find the best reception. deliver an acoustic signal to the ear.
  • Page 9: Direct Audio Input

    Using tele-loop systems Low Battery Warning Many gathering places such as schools, theatre and houses of worship, Your hearing care professional can activate a Low Battery Warning are equipped with tele-loop systems. To take advantage of such a function in your hearing instruments. When the battery voltage/power system, select the telecoil program to pick up direct sound.
  • Page 10: Maintenance

    Maintenance Cleaning the earmould daily Maintenance The earmould should be cleaned regularly: It is important to keep your hearing 1. Remove the earmould and the tubing from the hearing instrument instrument clean and dry every day. To before you clean it. clean the instrument, use a soft cloth.
  • Page 11: Replacing The Sound Outlet Filter

    Your ReSound Ziga hearing instrument is equipped with If your ReSound hearing instrument malfunctions it must be repaired a filter. This filter is located at the top of the sound outlet by a qualified technician. Do not attempt to open the case of the hear- and prevents moisture and debris from getting into the ing instrument since this will invalidate the warranty.
  • Page 12 General Precautions . Due to choking hazard hearing instrument usage by children or mentally challenged persons should be supervised at all times. 1. Do not leave your hearing instrument in the sun, near an open fire or in a 6. Hearing instruments should be used only as prescribed by your hearing hot, parked car.
  • Page 13: Troubleshooting Guide

    Troubleshooting Guide sYMPTOM CAUse POssiBLe reMedY No sound • Stand By Mode • Re-activate by pushing the programme selector once • Not turned on • Turn on by closing the battery door • Dead single use battery • Replace battery •...
  • Page 14 Troubleshooting Guide sYMPTOM CAUse POssiBLe reMedY squealing • Loose earmould • Remove and reinsert • The Dual Stabilizer II • Consult your hearing care professional system needs re-initialization • Build-up of earwax • Consult your physician • Instrument settings not optimal •...
  • Page 15: Key Word Index

    Key Word index Sound dissapeared..........4,6 Advice/Adjusting to the hearing aid .
  • Page 17 Oxon OX SX Auckland Tel.: 0 1869 4 00 Tel.: (free) 0800 900 16 Fax: 0 1869 4 466 Fax: (free) 0800 007 69 www.gnresound.co.uk www.gnresound.co.nz Any issues relating to the EU Medical Device Directive 9/4/EEC should be directed to ReSound A/S.

This manual is also suitable for:

Ziga zg80-dvi