APPLICATIONS

Tightening and loosening of all types of bolts and nuts,
used for securing structural items
REMOVAL AND INSTALLATION METHOD
OF BATTERY
1. Battery removal
Hold the handle tightly and push the battery latch to
remove the battery (see Fig. 5).
CAUTION
Never short-circuit the battery.
2. Battery installation
Insert the battery while observing its polarities (see
Fig. 5).
Insert
Pull out

CHARGING METHOD

NOTE
Before plugging into the receptacle, make sure the
following points.
○ The power source voltage is stated on the nameplate.
○ The cord is not damaged.
WARNING
Do not charge at voltage higher than indicated
on the nameplate.
If charged at voltage higher than indicated on the
nameplate, the charger will burn out.
12

ASSEMBLY AND OPERATION

Handle
Latch
Push
Battery
Fig. 5
1. Connect the charger's power cord to a receptacle.
When the power cord is connected, the charger's pilot
lamp will blink in red. (At 1-second intervals)
WARNING
Do not use the electrical cord
if damaged. Have it repaired
immediately.
2. Insert the battery to the battery charger.
Insert the battery into the battery charger as shown in
Fig. 6.
<UC18YFSL>
Pilot lamp
Charger
3. Charging
When the battery is connected to the battery charger,
charging will commence and the pilot lamp will light in
red. (See Table 2)
NOTE
If the pilot lamp fl ikers in red, pull out the plug from
the receptacle and check if the battery is properly
mounted.
When the battery is fully charged, the pilot lamp
will blink in red slowly. (At 1-second intervals) (See
Table 2)
(1) Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 2, according to the condition of the charger or
the rechargeable battery.