Circuit Breaker; Peripheral Equipment - Panasonic AC Servo MINAS E Series IMC80A Operating Manual

Panasonic power supply operating manual
Table of Contents

Advertisement

Peripheral Equipment

Environment
The servo driver should be used under Contamination Level 2 or 1 specified by IEC60664-1 (housing the driver in
an IP54 control box).
Insulating
transformer
Power
Power
Single-phase 100V: Single-phase 100V
Single-phase 200V: Single-phase 200V
Three-phase 200V: Three-phase 200V
(1) Use under the environment of Over-voltage Category II specified by IEC60664-1
In order to realize the environment of overvoltage category II, install in the power supply input unit an insulating
transformer that is compliant with ICE or EN standard (EN 60742).
(2) The power for interface should be marked CE or appropriate EN Standard type (EN60950), 12VDC to 24VDC,
insulated.

Circuit Breaker

Install a circuit breaker between the power supply and noise filter. The circuit breaker should be IEC Standard and
UL listed
marked.
Circuit
Leakage
breaker
breaker(RCD)
Surge
absorber
+ 10%
to 115V
- 15 %
+ 10%
to 240V
- 15 %
+ 10%
to 240V
- 15 %
Control box
Controller
Power supply for
insulated type
interface
AC servo
driver
Noise filter for
signal lines
CN X1
L1
Noise filter
L2
L3
Protective earth (PE)
+ 10%
50/60Hz
- 15 %
+ 10%
50/60Hz
- 15 %
+ 10%
50/60Hz
- 15 %
181
[Reference]
CN X5
Noise filter for
signal lines
AC servo
CN
driver
X3
U
V
M
W
E
RE
CN X4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Minas-e series

Table of Contents