4-4-9 O.C(Over Current) error

1.Checklist :
1) Is the IPM Shunt(PF2:R451,R452,R453,PF3:R413,R414,R415) resistance value correct? Check the resistor is opened
2) Is the condition of surrounding temperature abnormal overload?
3) Is there any problem as like the temperature sensor separation or measurement value error?
4) Is the interphase resistance of compressor normal?
2. Troubleshooting procedure
Restart after power off.
Is the O.C error occurred?
Is the connection of compressor wire is
normal?
Is the restart error occurred again?
Is the condition of indoor/outdoor
temperature normal load?
Is the position of temperature sensor and
sensing value normal?
Is the compressor body and interphase
resistance insulated?
Exchanged the Compressor
4-38
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
Restart after returning to the normal load
Is the O.C error
Yes
occurred again?
No
Yes
Terminate the service
Connect the comp wire normally
Terminate the service
No
Terminate the service
Correct the sensor position or exchange the
sensor
Exchange the Outdoor PBA