Water Drainage; Dump Valve Version; Machines With A Drain Pump - Miele PW 6080 Vario Operating And Installation Instructions

Table of Contents

Advertisement

Installation

Water drainage

Dump valve version

A motorised dump valve is used to
drain the machine. A DN 70 angle
connector can be used for draining the
machine via an on-site gully (with odour
trap). N.B. If not supplied with the
machine, an angle connector is
available to order from Miele.

Machines with a drain pump

The machine drains via a drain pump
with a delivery head of 1 metre*. The
drain hose must not be kinked as this
restricts drainage. The swivel elbow at
the end of the hose can be turned in
either direction, or can be detached if
required, with a sharp twist and pull.
Drain hose connection:
1. Connected securely to a plastic
drain pipe with a rubber nipple.
There is no need to use a non-return
valve.
2. Connected securely to a standpipe.
3. Connected securely to a floor gully.
If required, the drain hose can be
extended to a length of 5 m. The
necessary parts can purchased from
the Miele Spare Parts Department.
* For a delivery head of more than 1 m
(up to a max. of 1.6 m) a second
duo-drain pump is available with the
corresponding kit from the Miele Spare
Parts Department.
60

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents