DIVAtop F 24
Connection with separate pipes
C
B
C
52
22
12
fig. 23 - Examples of connection with separate pipes (
= Air /
= Fumes)
For connection of the separate ducts, fit the unit with the following starting accessory:
80
80
010011X0
fig. 24 - Starting accessories for separate ducts
Before proceeding with installation, make sure the maximum permissible length has not been exceeded, by means of
a simple calculation:
1. Establish the layout of the system of split flues, including accessories and outlet terminals.
2. Consult the table 4 and identify the losses in m
(equivalent metres) of every component, according to the instal-
eq
lation position.
3. Check that the sum total of losses is less than or equal to the maximum permissible length in table 3.
Table. 3 - Max. length for separate ducts
Separate ducts
Max. permissible length
60 m
eq
16