4.2.2.
Alarm settings
[2 SET ALMS]
In the alarm settings you can set a dive time alarm
and a maximum depth alarm. To enter Alarm settings
select MODE - SET - SET ALARMS (Fig. 4.18).
4.2.2.1.
Dive Time Alarm Setting
The instrument has one Dive Time Alarm Setting,
which can be used for several purposes to add to your
diving safety. The alarm can be set, for example, to
your planned bottom time.
Set the Dive Time alarm ON or OFF and the alarm
time from 1 to 999 minutes. (Fig. 4.19).
4.2.2.2.
Maximum Depth
Alarm Setting
You can set one depth alarm in the dive computer.
The depth alarm is set to 40 m [131 ft] at the factory,
but you are able to adjust it according your personal
preference or switch it off. The depth range can be set
from 3.0 m to 100 m [9 ft to 328 ft] (Fig. 4.20.).
SELECT
Fig. 4.18 Set Alarms Mode
OK
DIVE
TIME
Fig. 4.19. Setting Dive Time
Alarm. Press scroll buttons
to change alarm on/off and
to set dive time value.
m
MAX
OK
Fig. 4.20. Setting Maximum
Depth Alarm. Press scroll
buttons to change alarm on/
off and to set maximum
depth value.
45