Service Facts

Split System

Cooling
4TTA3030AD000A, 4TTA3036AD000A, 4TTA3042AD000A,
4TTA3048AD000A, 4TTA3060AD000A
IMPORTANT — This document contains a wiring diagram, a parts list, and service information. This is customer property and
is to remain with this unit. Please return to service information pack upon completion of work.
WARNING:

PRODUCT SPECIFICATIONS

4TTA3030AD000A
OUTDOOR UNIT
380-415/3/50
POWER CONNS. — V/PH/HZ 1
MIN. BRCH. CIR. AMPACITY
15
BR CIR PROT RTG – MAX. (AMPS)
SCROLL
COMPRESSOR
1 - 1
NO. USED - NO. SPEEDS
380-415/3/50
VOLTS/PH/HZ
6.1 - 38.0
R.L. AMPS 5 - L.R. AMPS
FACTORY INSTALLED
NO
START COMPONENTS 6
NO
INSUL/SOUND BLANKET
YES
COMPRESSOR HEAT
PROPELLER
OUTDOOR FAN
27.6 - 1
DIA. (IN.) - NO. USED
DIRECT - 1
TYPE DRIVE - NO. SPEEDS
3525
CFM @ 0.0 IN. W.G. 2
1 - 1/6
NO. MOTORS - HP
700
MOTOR SPEED R.P.M.
380-415/3/50
VOLTS/PH/HZ
0.7
F.L. AMPS
SPINE FIN™
OUTDOOR COIL — TYPE
1 - 24
ROWS - F.P.I.
24.93
FACE AREA (SQ. FT.)
3/8
TUBE SIZE (IN.)
R-410A
REFRIGERANT
TXV/Capillary
REFRIGERANT CONTROL
7 LBS., 11 OZ.
LBS — R-410A (O.D. UNIT) 3
YES
FACTORY SUPPLIED
3/4
LINE SIZE - IN. O.D. GAS 4
3/8
LINE SIZE - IN. O.D. LIQ. 4
CHARGING SPECIFICATION
10°F
TXV SYS CHGD TO SUBCOOL
10°F
CAPILLARY SYS CHGD TO SUPERHEAT
H X W X D
DIMENSIONS
42.4 x 35.1 x 38.7
CRATED (IN.)
WEIGHT
217
SHIPPING (LBS.)
182
NET (LBS.)
!
THIS
INFORMATION
IS
INTENDED
POSSESSING
ADEQUATE
BACKGROUNDS
MECHANICAL EXPERIENCE. ANY ATTEMPT TO REPAIR A CENTRAL AIR
CONDITIONING PRODUCT MAY RESULT IN PERSONAL INJURY AND
OR PROPERTY DAMAGE. THE MANUFACTURER OR SELLER CANNOT
BE RESPONSIBLE FOR THE INTERPRETATION OF THIS INFORMATION,
NOR CAN IT ASSUME ANY LIABILITY IN CONNECTION WITH ITS USE.
NOTICE: The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
© 2013 Trane
HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE
4TTA3036AD000A
4TTA3042AD000A
380-415/3/50
380-415/3/50
9
11
12
19
21
SCROLL
SCROLL
1 - 1
1 - 1
380-415/3/50
380-415/3/50
6.7 - 43.0
6.9 - 52.0
NO
NO
NO
NO
YES
YES
PROPELLER
PROPELLER
27.6 - 1
27.6 - 1
DIRECT - 1
DIRECT - 1
3525
3525
1 - 1/6
1 - 1/6
700
700
380-415/3/50
380-415/3/50
0.7
0.7
SPINE FIN™
SPINE FIN™
1 - 24
1 - 24
24.93
27.86
3/8
3/8
R-410A
R-410A
TXV/Capillary
TXV/Capillary
8 LBS., 8 OZ.
8 LBS., 6 OZ.
YES
YES
7/8
7/8
3/8
3/8
10°F
10°F
10°F
10°F
H X W X D
H X W X D
42.4 x 35.1 x 38.7
46.4 x 35.1 x 38.7
254
277
219
240
WARNING
FOR
USE
BY
OF
ELECTRICAL
UNIT CONTAINS R-410A REFRIGERANT!
R-410A OPERATING PRESSURE EXCEEDS THE
LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS
REQUIRED. FAILURE TO USE PROPER SERVICE
TOOLS MAY RESULT IN EQUIPMENT DAMAGE OR
PERSONAL INJURY.
CAPACITORS BEFORE SERVICING
4TTA3048AD000A
4TTA3060AD000A
380-415/3/50
380-415/3/50
12
14
21
25
SCROLL
SCROLL
1 - 1
1 - 1
380-415/3/50
380-415/3/50
7.6 - 51.5
8.9 - 67.1
NO
NO
NO
NO
YES
YES
PROPELLER
PROPELLER
27.6 - 1
27.6 - 1
DIRECT - 1
DIRECT - 1
3980
3980
1 - 1/6
1 - 1/6
700
700
380-415/3/50
380-415/3/50
0.7
0.7
SPINE FIN™
SPINE FIN™
1 - 24
1 - 24
30.79
30.79
3/8
3/8
R-410A
R-410A
TXV/Capillary
TXV/Capillary
9 LBS., 13 OZ.
9 LBS., 14 OZ.
YES
YES
7/8
7/8
3/8
3/8
10°F
10°F
10°F
10°F
H X W X D
H X W X D
51 x 35.1 x 38.7
51 x 35.1 x 38.7
292
297
255
260
INDIVIDUALS
RECONNECT ALL GROUNDING DEVICES.
AND
ALL PARTS OF THIS PRODUCT CAPABLE OF CONDUCTING
ELECTRICAL CURRENT ARE GROUNDED. IF GROUNDING
WIRES, SCREWS, STRAPS, CLIPS, NUTS OR WASHERS USED
TO COMPLETE A PATH TO GROUND ARE REMOVED FOR
SERVICE, THEY MUST BE RETURNED TO THEIR ORIGINAL
POSITION AND PROPERLY FASTENED.
4TTA3AD-SF-1A
CAUTION
!
SERVICE
USE ONLY R-410A REFRIGERANT AND
APPROVED POE COMPRESSOR OIL.
TUBING INFORMATION
REFRIGERANT TO ADD AT SPECIFIED
LINE TYPE
Suction
Liquid
20 ft
3/4"
3/8"
3 oz
7/8"
3/8"
3 oz
Tubing lengths in excess of sixty (60) feet see application software.
1 Calculated in accordance with Natl. Elec. Codes. Only use
HACR circuit breakers or fuses.
2 Standard Air — Dry Coil — Outdoor
3 This value approximate. For more precise value see unit nameplate.
4 Max. linear length 80 ft.; Max. lift - Suction 60 ft.; Max lift - Liquid
60 ft. For greater length consult refrigerant piping software Pub.
No. 32-3312-0* (* denotes latest revision).
5 This value shown for compressor RLA on the unit nameplate
and on this specification sheet is used to compute minimum
branch circuit ampacity and max. fuse size. The value shown is
the branch circuit selection current.
6 No means no start components. Yes means quick start kit com-
ponents. PTC means positive temperature coefficient starter.
CAUTION
!
HOT SURFACE!
DO NOT TOUCH TOP OF COMPRESSOR.
May cause minor to severe burning.
CAUTION
!
CONTAINS REFRIGERANT!
SYSTEM CONTAINS OIL AND REFRIGERANT UNDER
HIGH PRESSURE. RECOVER REFRIGERANT TO RELIEVE
PRESSURE BEFORE OPENING SYSTEM.
Failure to follow proper procedures can result in personal
illness or injury or severe equipment damage.
CAUTION
!
ADDITIONAL LENGTH
30 ft
40 ft
50 ft
60 ft
9 oz
15 oz
21 oz
27 oz
9 oz
16 oz
22 oz
28 oz
10/13

Advertisement

Table of Contents
loading

Summary of Contents for Trane 4TTA3030AD000A

  • Page 1: Split System

    TOOLS MAY RESULT IN EQUIPMENT DAMAGE OR Cooling PERSONAL INJURY. SERVICE 4TTA3030AD000A, 4TTA3036AD000A, 4TTA3042AD000A, USE ONLY R-410A REFRIGERANT AND 4TTA3048AD000A, 4TTA3060AD000A APPROVED POE COMPRESSOR OIL. IMPORTANT — This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit.
  • Page 2: Schematic Diagram

    SCHEMATIC DIAGRAM SUBCOOLING CHARGING IN COOLING ABOVE 55°F OD AMBIENT The manufacturer has always recommended installing approved to lower the pressure. Again, wait 20 minutes for the system matched indoor and outdoor systems. conditions to stabilize before adjusting charge again. All split systems are AHRI rated with only TXV indoor systems.
  • Page 3: Wiring Diagram

    WIRING DIAGRAM SUBCOOL CHARGING CHART CORRECTIONS TABLE (FOR LINE LENGTH AND RISE) SUBCOOL CHARGING CHART CORRECTIONS TABLE (FOR LINE LENGTH AND RISE) Add 4° Add 5° Add 3° Add 4° Add 2° of Subcooling Add 3° of Subcooling Add 1° of Subcooling Add 2°...
  • Page 4: Troubleshooting

    TROUBLESHOOTING 4TTA3AD-SF-1A...
  • Page 5 REFRIGERANT CIRCUIT 4TTA3030AD, 036AD, 42AD Printed from D157878 REFRIGERANT CIRCUIT 4TTA3048AD/060AD Printed from D157826 4TTA3AD-SF-1A...
  • Page 6 PRESSURE CURVES FOR 4TTA3030AD PRESSURE CURVES FOR 4TTA3030AD MCDA30 GAF2A0A36 Cooling with FCCV or Capillary Tubes Cooling with Thermal Expansion Valve INDOOR ENTERING INDOOR ENTERING WET BULB CURVES WET BULB CURVES TOP TO BOTTOM TOP TO BOTTOM 71, 67, 63 AND 59 DEG F. 71, 67, 63 AND 59 DEG F.
  • Page 7 PRESSURE CURVES FOR 4TTA3036AD PRESSURE CURVES FOR 4TTA3036AD GAF2A0A36 MCDA36 Cooling with Thermal Expansion Valve Cooling with FCCV or Capillary Tubes INDOOR ENTERING INDOOR ENTERING WET BULB CURVES WET BULB CURVES TOP TO BOTTOM TOP TO BOTTOM 71, 67, 63 AND 59 DEG F. 71, 67, 63 AND 59 DEG F.
  • Page 8 PRESSURE CURVES FOR 4TTA3060AD PRESSURE CURVES FOR 4TTA3060AD MCDB60 GAF2A0A60 Cooling with FCCV or Capillary Tubes Cooling with Thermal Expansion Valve INDOOR ENTERING INDOOR ENTERING WET BULB CURVES WET BULB CURVES TOP TO BOTTOM TOP TO BOTTOM 71, 67, 63 AND 59 DEG F. 71, 67, 63 AND 59 DEG F.

This manual is also suitable for:

4tta3036ad000a4tta3042ad000a4tta3048ad000a4tta3060ad000a4ttb3018aa000a4ttb3024aa000a ... Show all

Table of Contents