Daikin FTXM-K Series Service Manual page 42

Inverter pair
Table of Contents

Advertisement

Main Functions
2. The motions (in cooling)
Human detection
signal
Target temperature
Remote controller
INTELLIGENT
EYE button
Operation
Fan speed ( )
3. Airflow direction in 2-area INTELLIGENT EYE operation
1. Detection signal ON in both area A and B: Shift the airflow direction to area B (left side)
2. Detection signal ON in area A: Shift the airflow direction to area B (left side)
3. Detection signal ON in area B: Shift the airflow direction to area A (right side)
4. Detection signal OFF in both area A and B: No change
*When the detection signal is OFF for 20 minutes in both area A and B, the unit starts energy
saving operation.
Note:
For dry operation, the temperature cannot be set with a remote controller, but the target
temperature is shifted internally.
27
within
20 min.
ON
OFF
Reset
ON
OFF
ON
OFF
OFF
In FAN operation, the fan speed is reduced by 60 rpm.
When the microcomputer does not have a signal from the sensor in 20 minutes, it judges
that nobody is in the room and operates the unit at a temperature shifted from the target
temperature. (cooling / dry: 1 ~ 2°C higher, heating: 2°C lower, automatic: according to the
operation mode at that time.)
Detection method: The opposite area of detected area is set as the target direction.
Left
20 min.
Set speed
Indoor unit
Human
Area A
Area B
within
20 min.
Reset
Set speed
Wall
Top view
Right
(R3853)
Function and Control
SiBE041434E
within
20 min.
Reset
(R19414)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents