Allen-Bradley PowerFlex 753 Quick Start Manual page 69

Powerflex 750 series
Table of Contents

Advertisement

Table 44 - Acceleration and Deceleration Parameter Settings
No.
Parameter Name User Setting
535
Accel Time 1
537
Decel Time 1
422
Current Limit 1
Values
Units:
Secs
Default:
10
Min/Max:
0.00 / 3600.00
Units:
Secs
Default:
10
Min/Max:
0.00 / 3600.00
Units:
Amps
Default:
Based on drive rating
and ND/HD selection
Min/Max:
Based on drive rating
Rockwell Automation Publication 750-QS001A-EN-P - March 2015
Notes
Sets the acceleration rate for all speed changes and is
dependent on inertia and acceleration torque. Also, set
parameter 422 [Current Limit 1] to drive rating.
For more information, see
Acceleration Time on page
Sets the deceleration rate for all speed changes and is
dependent on inertia and deceleration torque.
Decel rate can affect the extent of the dynamic braking needed.
Increase the decel rate to reduce regenerative energy demand or
increase the dynamic brake capacity.
For more information, see
Deceleration Time on page 68
PowerFlex Dynamic Braking Resistor Calculator Application
Technique, publication PFLEX-AT001.
Current setting above continuous current rating of the drive is
time limited. Refer to the Recommendation in
Time on page
68.
Reference Section
68.
or the
Acceleration
69

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PowerFlex 753 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Powerflex 755

Table of Contents

Save PDF