Force Bulk or Float: Pushing the button under FLOAT or BULK will force the charger into that charge state.
PCB:
Temperature measurement value used to control the cooling fan's operation and overtemperature
protection. The temperature measurement is not the actual internal temperature but as a reference
value.
CmpV:
Compensated voltage that the controller is using as a target for voltage regulation.
Btmp:
Battery temperature sensor reference value used to compensate the charging process.
This is an arbitrary between 0 and 255 and is not the actual temperature.
GMR:
Output value of the current sensor used to calculate output amps, watts, and track the PV array.
Totlkwh:
Total kW hours accumulated every night from daily KWh. Pressing and holding "Clrw" for 3 seconds
clears this value. The daily KWH are added to the counter at the end of each day.
EndA:
Normally an absorb charge cycle is timed. Decreasing (Dec) or increasing (Inc) sets the optional
end current level in Amps. While the controller is regulating the charging process in the absorb
tion stage and the end current level is reached before the charge timer has reached zero (ChgT
in Figure 13), the MX60 will switch to float charge mode. This is an optional setpoint and is not required
to be adjusted in most installations.
Figure 14 Miscellaneous Screen 2
Figure 15 Miscellaneous Screen 3
PRESS "NEXT" TO
CONTINUE TO THE
MISCELLANEOUS
SCREEN NO. 3
PRESS "EXIT" TO
RETURN TO THE
MAIN STATUS SCREEN
12