5.1.6. To reset the breaker do the following;
5.1.6.1.
5.1.6.2.
output.
5.1.7. Wait a few minutes before resuming operation.
5.2. Electrical appliances, particularly motor driven equipment, will have a very high start-up
current. The table below provides reference for connecting these appliances to the
generator.
Type
Lighting
Heating
Appliance
Fluorescent
Lamp
Motor
Driven
Equipment
6. STOPPING MACHINE
• Do not stop the engine suddenly or whilst under load.
• This can damage the AVR and cause damage to the alternator through
overheating.
• Do not stop the engine with the decompression lever.
6.1. Switch OFF equipment connected to the generator.
6.2. Turn off the main breaker switch.
6.3. Run the generator without load for three minutes.
6.4. Turn the electric key start switch to the 'OFF'
position.
6.5. Or press or pull down the stop lever.
Turn OFF and disconnect all loads.
Reset breaker, and add load onto the circuit to within 50% to 75% of rated
Wattage
Starting
Rated
x 1
x 1
x 2
x 1 to x 1.5
x 3.5
x 1 to 2
Typical
appliance
Appliance
Incandescent
Incandescent
lamp or heating
lamp 1000
appliance
watts
Fluorescent
Fluorescent Lamp
Lamp
Refrigerator,
Electric fan,
Refrigerator 150
Compressor or
grinder
Page 19
Example
Starting
100 vA
80 vA
450 to 750
watts
vA
Rated
100 vA
40 to 60
vA
150 to 30
vA
Rev 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dhy6000lrDhy8000seDhy8000lrDhy8000selr-t

Table of Contents