Remote Control Pass-Through Mode - ViewSonic CDX4952 User Manual

Table of Contents

Advertisement

4. Get Date & Time example
Assumed the current date/time of display#01 as below
Date: 2015-1/31
Time: 16:27:59
Send: 0x 38 30 31 67 32 30 30 30 0D (Get Date)
Reply:
#1
0x 38 30 31 72 32 30 40 35 0D (Year "20" "15")
#2
0x 38 30 31 72 32 31 21 51 0D (Month "1", Day "31")
Send: 0x 38 30 31 67 33 30 30 30 0D (Get Time)
Reply:
#1
0x 38 30 31 72 33 30 36 47 0D (Hour "16", Min "27")
#2
0x 38 30 31 72 33 31 30 79 0D ("0", Sec "59")

10.3.3. Remote Control Pass-through mode

When the PC sets the TV/DS to Remote Control Pass through mode, the TV/DS will send a 7-byte packet
(followed by "CR") in response to RCU button activation. Note, that in this mode the RCU shall have no
effect on the TV/DS function. For example: "Volume+" will not change the volume in the LCD but only sends
"Volume+" code to PC over the RS232 port.
IR Pass Through-Function format
Reply: (Command Type="p")
Name
Length
Byte Count
1 Byte
Bytes order
1
Example1: Remote Control pass-through when "VOL+" key is pressed for TV-05 Send (Hex Format)
Name
Length
Hex
0x36
Command
ID
Type
2 Byte
1 Byte
2~3
4
Command
ID
Type
0x30
0x70
0x35
44
RCU Code1
RCU Code2
(MSB)
(LSB)
1 Byte
1 Byte
5
6
Command
Value1
0x31
0x30
CR
1 Byte
7
CR
0x0D