Salter BPW-9100 Instructions And Guarantee

Salter BPW-9100 Instructions And Guarantee

Fully automatic electronic blood pressure monitor

Advertisement

E
E
BLOOD PRESSURE MONITOR
BLOOD PRESSURE MONITOR
Instructions and Guarantee
Instructions and Guarantee
BPW-9100

Advertisement

Table of Contents
loading

Summary of Contents for Salter BPW-9100

  • Page 1 BLOOD PRESSURE MONITOR BLOOD PRESSURE MONITOR Instructions and Guarantee Instructions and Guarantee BPW-9100...
  • Page 2: Normal Blood Pressure Fluctuation

    GUARANTEE Salter will repair or replace the product, or any part of this product, free of charge if within 2 years of the date of purchase, it can be shown to have failed through defective workmanship or materials. This guarantee covers working parts that affect the function of the blood pressure monitor.
  • Page 3: Contents And Display Indicators

    CONTENTS AND DISPLAY INDICATORS LCD display MEM button Blood Pressure Level Classification Indicator START button Cuff Date/Time Display Memory Indicator Low Battery Indicator Systolic Pressure Blood pressure level Classification Indicator Diastolic Pressure/ Pulse Rate Display Irregular heartbeat symbol (Alternating) Ready to inflate indicator INTENDED USE Fully Automatic Electronic Blood Pressure Monitor is for use by medical professionals or at home and is a non-invasive blood pressure measurement system intended to measure the diastolic and systolic blood pressures and pulse rate of an...
  • Page 4: Product Description

    ANSI/AAMI SP-10:2002+A1:2003+A2:2006 SPECIFICATIONS Product name: Blood Pressure Monitor Model BPW-9100 Internally powered, Type BF applied part,IPX0,No AP or Classification APG,Continuous operation Machine size Approx. 85mm x 64.5mm x 28mm (3 11/32”x 2 17/32”x 1 3/32”)
  • Page 5 NOTICE 1. Read all of the information in the operation guide and any other literature in the box before operating the unit. 2. Stay still, calm and rest for 5 minutes before blood pressure measurement. 3. The cuff should be placed at the same level as your heart. 4.
  • Page 6: Setup And Operating Procedures

    17. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 18.
  • Page 7 3. CONNECTING THE CUFF TO THE MONITOR The cuff is attached to the monitor when it is packaged. Should the cuff become unattached, align the two plugs and four brackets of the cuff with the plug sockets and bracket sockets of the monitor and press the cuff to the monitor until the plugs and brackets are securely attached.
  • Page 8: Displaying Stored Results

    7. DISPLAYING STORED RESULTS a. After measurement, you can review the results in the memory bank by pressing the “MEM” button. Alternatively, you can press “MEM” button in Clock Mode to display the stored results. If it no result stored, LCD will show dashes as picture 7, while press the button “MEM”...
  • Page 9: Assessing High Blood Pressure For Adults

    9. ASSESSING HIGH BLOOD PRESSURE FOR ADULTS The following guidelines for assessing high blood pressure (without regard to age or gender) have been established by the World Health Organization (WHO). Please note that other factors (e.g. diabetes, obesity, smoking, etc.) need to be taken into consideration.
  • Page 10 11. TROUBLESHOOTING (2) PROBLEM POSSIBLE CAUSE SOLUTION LCD shows low battery symbol Change the batteries LCD shows low battery symbol LCD shows “Er 0” Pressure system is unstable before measurement LCD shows “Er 1” Fail to detect systolic pressure Don’t move and try again. LCD shows “Er 1”...
  • Page 11: Explanation Of Symbols On Unit

    EXPLANATION OF SYMBOLS ON UNIT Symbol for” THE OPERATION GUIDE MUST BE READ”(The sign background colour: blue.The sign graphical symbol: white) Symbol for “WARNING” Symbol for “TYPE BF APPLIED PARTS” (The cuff is type BF applied part) Symbol for “ENVIRONMENT PROTECTION – Waste electrical products should not be disposed of with household waste.
  • Page 12: Electromagnetic Compatibility Information

    Guidance and manufacture’s declaration – electromagnetic emission The [BPW-9100] is intended for use in the electromagnetic environment specified below. The customer or the user of the [BPW-9100] should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment - guidance The [BPW-9100] uses RF energy only for its internal function.
  • Page 13 To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the [BPW-9100] is used exceeds the applicable RF compliance level above, the [BPW-9100] should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the [BPW-9100].
  • Page 14 The [BPW-9100] is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the [BPW-9100] can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the [BPW-9100] as recommended below, according to the maximum output power of the communications equipment.
  • Page 16 Register your product today at: www.homedicsgroup.com/register 0120 HoMedics Group Ltd HoMedics House, Somerhill Business Park, Five Oak Green Road, Tonbridge, Kent TN11 0GP, UK. www.salterhousewares.co.uk IB-BPW-9100-GB-0314-01...