Pioneer pdp-433cmx Service Manual page 116

Hide thumbs Also See for pdp-433cmx:
Table of Contents

Advertisement

1
A
GS1:
Outputting data such as version information, and data from the hour meter and pulse meter
• Data are output according to the transmission order and size of the table below.
• This command is invalid in modes other than RS-232C Factory Adjustment mode.
Order
1
Display information
2
Module microcomputer model number
3
Module microcomputer version
4
Panel microcomputer version
5
Panel /FLASH ROM version
6
Hour meter (hour)
B
7
Pulse meter
8
Main microcomputer model number
9
Main microcomputer version
10
Wide microcomputer version
11
Wide /FLASH ROM version
Display Information
Data
MX5
PDP-503CMX/MXE (initial value)
C
MX4
PDP-433CMX/MXE
MD5
Module 50 inches
MD4
Module 43 inches
HD5
PDP-503HD
HD4
PDP-433HD
GS2:
Outputting data for power down, temperature and condensation information
• Data are output according to the transmission order and size in the table below.
• This command is valid only in the following cases: in RS-232C Factory adjustment mode, during power-down or shutdown, and for 30
seconds until a shutdown occurs because of condensation formed inside the unit or audio failure.
D
Note: During power-down, when a failure occurs, or for 30 seconds until a shutdown occurs, data can be obtained by directly executing
"GS2" without executing "FAY." However, the ID must be set beforehand.
Order
1
AC information
2
Service parts distinction
3
Hour meter (hour, minute)
4
Power-down information
5
Temperature information
6
Condensation information
E
7
Panel microcomputer communication
8
DIGITAL EEPROM communication
9
DIGITAL EXPANDER communication
10
Temperature information (TEMP2)
11
Temperature information (TEMP3)
12
Module microcomputer communication
13
Wide microcomputer communication
14
MAIN IIC
15
MAIN EEPROM IIC
16
AUDIO failure
F
17
FAN failure
116
1
2
Data Contents
Model
Data Contents
PDP-433CMX
2
3
Size
Remarks
3 byte
See below
4 byte
5691 or F691
3 byte
3 byte
3 byte
5 byte
Unit: H (hour)
7 byte
Unit: 0.01G (10,000,000)
4 byte
5692
3 byte
3 byte
3 byte
Size
Remarks
1 byte
Always 0 (not used)
0: DIGITAL ASSY adjustment done
1 byte
1: DIGITAL ASSY not adjusted (Service Assy)
7 byte
*****H**M
2 byte
1st/2nd (∗)
3 byte
8 bit
1 byte
1: Condensation
1 byte
1: Communication failure
1 byte
1: Communication failure
1 byte
1: Communication failure
3 byte
8 bit
3 byte
8 bit
1 byte
1: Communication failure
1 byte
1: Communication failure
1 byte
1: Communication failure
1 byte
1: Communication failure
1 byte
1: AUDIO failure
1 byte
1: FAN failure
3
4
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdp-433mxe

Table of Contents