USE & OPERATION (CONTINUED)
REMOTE CONTROL (CONTINUED)
Always point the remote control signal transmitter towards the unit when operating. Make sure that
the signal path is not obstructed.
Remove the batteries if the unit is not going to be used for an extended period of time.
Do not drop the remote control.
Do not mix different types of batteries such as alkaline, carbon-zinc, or rechargeable batteries.
Do not mix old and new batteries.
Do not recharge the battery.
Exhausted batteries are to be removed from the product and safely disposed of as per local
regulations.
Do not dispose of batteries in fire. Batteries may explode or leak.
WARNING: Caution for ingestion of the small battery. Keep away from children and animals.
COOLER LOCATION
Make sure to position the air cooler correctly before you set up and start using the product. Please refer
to the COOLER LOCATION section of the separate Safety & Maintenance Guide.
FILLING WITH WATER
CAUTION:
Unplug the unit from the electrical power outlet before emptying or refilling the
water tank.
Open the Water Fill Door located on the side of the unit.
The Water Level Indicator is located at the front of the unit. Refill the water tank
when water level is low. Do not fill water above the "Max." water level mark to
avoid water droplets collecting on the louvers. Check the water level in the tank
before running the COOL function. Make sure that the water in the tank is above
the minimum water level mark. Running the unit in COOL mode with inadequate
water may cause pump failure.
Note: The water capacity refers to the total volume of water that can be
contained within the air cooler water tank and water distribution system. The
water capacity in the tank at the "Max." indicator level may be lower than the
actual water capacity of the air cooler.
Note: If ice is available, you may add ice in the top ice compartment to enhance
the cooling performance.
LOW WATER ALARM
The unit is equipped with a low water sensor. In Cooling Mode, when water in the tank is below the
minimum level, you will hear a beeping sound and the TANK EMPTY indicator light will flash
continuously. The unit will automatically pause evaporative cooling.
Refill the water tank to deactivate the alarm in cooling mode. First switch OFF the unit and unplug from
the power outlet. Fill the water tank with water above the minimum water level mark. Plug in and switch
ON again.