Continuity; Resistance Measurements - Klein Tools CL700 Instruction Manual

600a ac auto-ranging digital clamp meter
Hide thumbs Also See for CL700:
Table of Contents

Advertisement

ENGLISH

CONTINUITY

1. Insert RED test lead into V jack
COM jack
Continuity/Resistance/Diode-Test
NOTE: The meter defaults to Continuity testing in this mode. Ensure
that the Continuity Testing icon
press the "SEL" button
2. Remove power from circuit.
3. Test for continuity by connecting conductor or circuit with test
leads. If resistance is measured less than 50Ω, an audible signal
will sound and display will show a resistance value indicating
continuity. If circuit is open, display will show "OL".
DO NOT attempt to measure continuity on a live circuit.

RESISTANCE MEASUREMENTS

1. Insert RED test lead into V jack
COM jack
Continuity/Resistance/Diode-Test
NOTE: The meter defaults to Continuity testing in this mode. Press
the "SEL" button
Resistance icon will appear on the display.
2. Remove power from circuit.
3. Measure resistance by connecting test leads to circuit. The
meter will auto-range to display the measurement in the most
appropriate range.
NOTE: When in a Resistance setting and the test leads are open
(not connected across a resistor), or when a failed resistor is under
test, the display will indicate O.L. This is normal.
DO NOT attempt to measure resistance on a live circuit.
12
CL700-1390105ART.indd 12
OPERATING INSTRUCTIONS
, and rotate function selector switch
4
Black lead Red lead
, and rotate function selector switch
4
once to enter Resistance testing mode. The
9
Black lead Red lead
Dwg Name: CL700-1390105ART
Dwg No: 1390105
ECO No: 21122
Pkg Dwg Ref: 1290186
Color Reference: N/A
, and BLACK test lead into
5
is visible on the display. If not,
repeatedly until the
9
, and BLACK test lead into
5
Rev: B
to the
2
setting.
icon is shown.
to the
2
setting.
12/4/2015 2:25:03 PM

Advertisement

Table of Contents
loading

Table of Contents