Download Print this page
Moxa Technologies NPort 5210A Quick Installation Manual

Moxa Technologies NPort 5210A Quick Installation Manual

Nport 5200a series
Hide thumbs Also See for NPort 5210A:

Advertisement

Quick Links

Quick Installation Guide

Moxa Americas:
Toll-free: 1-888-669-2872
Tel:
1-714-528-6777
Fax:
1-714-528-6778
Moxa Europe:
Tel:
+49-89-3 70 03 99-0
Fax:
+49-89-3 70 03 99-99
Moxa India:
Tel:
+91-80-4172-9088
Fax:
+91-80-4132-1045
NPort 5200A Series
Edition 2.0, December 2015
Technical Support Contact Information
www.moxa.com/support
 2015 Moxa Inc. All rights reserved.
Moxa China (Shanghai office):
Toll-free: 800-820-5036
Tel:
+86-21-5258-9955
Fax:
+86-21-5258-5505
Moxa Asia-Pacific:
Tel:
+886-2-8919-1230
Fax:
+886-2-8919-1231
P/N: 1802052000012
*1802052000012*

Advertisement

loading

Summary of Contents for Moxa Technologies NPort 5210A

  • Page 1: Quick Installation Guide

    NPort 5200A Series Quick Installation Guide Edition 2.0, December 2015 Technical Support Contact Information www.moxa.com/support Moxa Americas: Moxa China (Shanghai office): Toll-free: 1-888-669-2872 Toll-free: 800-820-5036 Tel: 1-714-528-6777 Tel: +86-21-5258-9955 Fax: 1-714-528-6778 Fax: +86-21-5258-5505 Moxa Europe: Moxa Asia-Pacific: Tel: +49-89-3 70 03 99-0 Tel: +886-2-8919-1230 Fax:...
  • Page 2: Package Checklist

    Overview NPort 5200A series device servers are compact, palm-sized data communication devices that allow you to control RS-232 (NPort 5210A), RS-422/485 (NPort 5230A), and RS-232/422/485 (NPort 5250A) serial devices over a TCP/IP-based Ethernet. NOTE “-T” indicates an extended temperature model.
  • Page 3 Reset Button—Press and hold the Reset button for 5 seconds to load factory defaults: Use a pointed object, such as a straightened paper clip or toothpick, to depress the reset button. This will cause the Ready LED to blink on and off. The factory defaults will be loaded once the Ready LED stops blinking (after about 5 seconds).
  • Page 4: Hardware Installation Information

    Hardware Installation Information STEP 1: After removing the NPort 5200A series device server from the box, connect the NPort 5200A series device server to a network. Use a standard straight-through Ethernet cable to connect to a hub or switch. When setting up or testing the NPort 5200A series device server, you might find it convenient to connect directly to your computer’s Ethernet port.
  • Page 5: Pin Assignments

    Pin Assignments Ethernet Port Pinouts Pin No. Ethernet NPort 5210A—DB9 male (RS-232) port pinouts Pin No. RS-232 – NPort 5230A—Terminal Block (RS-422/485) port pinouts Pin No. RS-422/485-4W RS-485-2W TxD+(B) – TxD-(A) – RxD+(B) Data+(B) RxD-(A) Data-(A) NPort 5250A—DB9 male (RS-232/422/485) port pinouts Pin No.
  • Page 6: Specifications

    Specifications Power Requirements Power Input 12 to 48 VDC Power Consumption 119 mA @ 12V, 65 mA @ 24V Environmental Limits Operating Temperature Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) Ambient Humidity 5 to 95% RH Dimensions...

This manual is also suitable for:

Nport 5250aNport 5230a