Genie gS-1530/32 Operator's Manual page 58

Hide thumbs Also See for gS-1530/32:
Table of Contents

Advertisement

Operator's Manual
Maintenance
Check the Batteries
Proper battery condition is essential to good
machine performance and operational safety.
Improper fluid levels or damaged cables and
connections can result in component damage and
hazardous conditions.
Note: This procedure does not need to be
performed on machines with sealed or
maintenance-free batteries.
Electrocution hazard. Contact with hot or live
circuits may result in death or serious injury.
Remove all rings, watches and other jewelry.
Bodily injury hazard. Batteries contain acid.
Avoid spilling or contacting battery acid.
Neutralize battery acid spills with baking soda
and water.
Note: Perform this test after fully charging the
batteries.
1
Put on protective clothing and eye wear.
2
Be sure that the battery cable connections are
tight and free of corrosion.
3
Be sure that the battery hold-down brackets
are in place and secure.
Note: Adding terminal protectors and a corrosion
preventative sealant will help eliminate the
corrosion on the battery terminals and cables.
56
Scheduled Maintenance
Maintenance performed quarterly, annually and
every two years must be completed by a person
trained and qualified to perform maintenance on
this machine according to the procedures found in
the service manual for this machine.
Machines that have been out of service for more
than three months must receive the quarterly
inspection before they are put back into service.
GS-30 • GS-32 • GS-46 • GS-47
Seventh Edition • Fifth Printing
Part No. T107028

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents