Config Guide

4. Controllers

4.1. Protocols – CNC (FC&iSCSI) & SAS
AssuredSAN 3xx4 controller architecture maximizes performance, including
Two host ports per controller
6GB transportable read/write cache per controller.
Battery-free cache backup with super capacitors and compact flash
1. CNC ports (0,1) shown with FC SFPs
2. CLI port
3. Service port 2 (used by service personnel only)
4. Reserved for future use
Single Controllers:
Single controllers are supported in the 2U12 and 2U24 but NOT recommended due to lack of failover
capability.

4.2. SFPs

For CNC versions (D38xxx), one four-pack set is advised. Both FC and iSCSI transceivers contain unique
identification preventing unqualified SFP's from being used in the 3xx4 (EX) controller.
Dot Hill branded SFP's must be ordered with the AssuredSAN 3xx4 controllers with the CNC (Converged Network
Controller). They are available in 4 packs, so quantity 1 is recommended. They are available in 1G iSCSI, 10G
iSCSI, 8G FC, or 16G FC. SAS and JBOD systems do not require SFP's.
TLAs for the SFPs for the 2U12 and 2U24 are below.
PFRUKK11
PFRUKK12
PFRUKK13
PFRUKK14
83-00006911-00-01 Rev B
3xx4 controller supports 8Gb FC, 16Gb FC, 1GbE iSCSI or 10GbE iSCSI SFPs.
3xx4 SAS controller supports 6Gb and 12Gb SAS host connectivity using mini-SAS HD Cables. (Also
supports four port-expansion (Y-cables) to enable up to four dual-port hosts to be attached.)
1
2
4
5
6
3
7
5. Network Port
6. Service Port 1 (used by service personnel only)
7. Disable button (used by engineering only)
8. Mini-SAS expansion port
SFP,1Gb Copper RJ45 -1D,4 Pack Set
SFP,8Gb 850nm Rate Select,4 Pack Set
SFP+,10GigE 3.3V 850nm LC Mod,4 Pack Set
SFP+,16GFC 3.3V 850nm LC Mod, 4 Pack Set