Chapter 4 Parameters|
Group 10 PID Control
In this group, ASR is short for the Auto Speed Regulation and PG is short for Pulse Generator.
10-00
Encoder Pulse
Control
VFPG FOCPG TQCPG
mode
Settings
A Pulse Generator (PG) or encoder is used as a sensor that provides a feedback signal of the
motor speed. This parameter defines the number of pulses for each cycle of the PG control.
10-01
Encoder Input Type Setting
Control
VFPG FOCPG TQCPG
mode
Settings
4-172
CALL NOW 800-985-6929
1 to 20000 (Max=20000 for 2-pole motor)
0
Disable
Phase A leads in a forward run command and phase B leads in a
reverse run command
FWD
1
A
B
Phase B leads in a forward run command and phase A leads in a
reverse run command
FWD
2
A
B
Phase A is a pulse input and phase B is a direction input. (low
input=reverse direction, high input=forward direction)
FWD
3
A
B
Phase A is a pulse input and phase B is a direction input. (low
input=forward direction, high input=reverse direction)
FWD
4
A
B
Single-phase input
5
A
CALL NOW 800-985-6929
http://www.automatedpt.com
Factory Setting: 600
Factory Setting: 0
REV
REV
REV
REV
Revision Dec. 2008, 04VE, SW V2.05
http://www.automatedpt.com
Unit: 1