Power Down The Server; Remove The Security Bezel; Extend The Front Drive Cages Out Of The Chassis - HP apollo 4200 gen9 Maintenance And Service Manual

Hide thumbs Also See for apollo 4200 gen9:
Table of Contents

Advertisement

Power down the server

Before powering down the server for any upgrade or maintenance procedures, perform a backup of
critical server data and programs.
IMPORTANT: When the server is in standby mode, auxiliary power is still being provided to
the system.
To power down the server, use one of the following methods:
Press and release the Power On/Standby button.
This method initiates a controlled shutdown of applications and the OS before the server enters
standby mode.
Press and hold the Power On/Standby button for more than 4 seconds to force the server to enter
standby mode.
This method forces the server to enter standby mode without properly exiting applications and the
OS. If an application stops responding, you can use this method to force a shutdown.
Use a virtual power button selection through iLO 4.
This method initiates a controlled remote shutdown of applications and the OS before the server
enters standby mode.
Before proceeding, verify the server is in standby mode by observing that the system power LED is
amber.

Remove the security bezel

To access the front panel components, unlock and then remove the security bezel.

Extend the front drive cages out of the chassis

WARNING: To reduce the risk of personal injury or damage to the equipment, adequately
stabilize the rack before extending a component outside the rack. Extend only one component
at a time. A rack may become unstable if more than one component is extended.
Removal and replacement procedures 26