Acs355 Drive Configuration - ABB ACS355 Application Manual

Machinery drive
Hide thumbs Also See for ACS355:
Table of Contents

Advertisement

10 Configuration

ACS355 drive configuration

The AC500 Modbus application macro makes the necessary changes to parameter default
values for use in the starter kit. To activate the macro, set parameter 9902 APPLIC
MACRO to AC500 MODBUS (10) as shown below. The macro is available in ACS355
drives with software version 503C or above.
Step Action
1.
Go to the Main menu by pressing
Output mode, otherwise by pressing repeatedly
you get to the Main menu.
2.
Go to the Parameters mode by selecting PARAMETERS
on the menu with keys
ENTER
.
3.
Select the appropriate parameter group with keys
and
.
SEL
Press
.
4.
Select the appropriate parameter with keys
. The current value of the parameter is shown
below the selected parameter.
EDIT
Press
.
5.
Specify a new value for the parameter with keys
and
.
Pressing the key once increments or decrements the
value. Holding the key down changes the value faster.
Pressing the keys simultaneously replaces the displayed
value with the default value.
6.
• To save the new value, press
• To cancel the new value and keep the original, press
CANCEL
.
The AC500 Modbus application macro default drive parameters correspond to the ABB
standard macro for ACS355, with the following changes:
Parameter
1001
EXT1 COMMANDS
1102
EXT1/EXT2 SEL
1103
REF1 SEL
1604
FAULT RESET SEL
MENU
if you are in the
EXIT
until
and
, and pressing
and
SAVE
.
Name
COMM (10)
COMM (8)
COMM (8)
COMM (8)
Display
LOC
MAIN MENU
1
PARAMETERS
ASSISTANTS
CHANGED PAR
00:00
EXIT
ENTER
LOC
PAR GROUPS
01
01 OPERATING DATA
03 FB ACTUAL SIGNALS
04 FAULT HISTORY
10 START/STOP/DIR
11 REFERENCE SELECT
EXIT
00:00
SEL
LOC
PAR GROUPS
99
99 START-UP DATA
01 OPERATING DATA
03 FB ACTUAL SIGNALS
04 FAULT HISTORY
10 START/STOP/DIR
EXIT
00:00
SEL
LOC
PARAMETERS
9901 LANGUAGE
ENGLISH
9902 APPLIC MACRO
9903 MOTOR TYPE
9904 MOTOR CTRL MODE
EXIT
00:00
EDIT
LOC
PARAMETERS
9901 LANGUAGE
9902 APPLIC MACRO
ABB STANDARD
9903 MOTOR TYPE
9904 MOTOR CTRL MODE
EXIT
00:00
EDIT
LOC
PAR EDIT
9902 APPLIC MACRO
ABB STANDARD
[1]
00:00
CANCEL
SAVE
LOC
PAR EDIT
9902 APPLIC MACRO
AC500 MODBUS
[10]
CANCEL
00:00
SAVE
LOC
PARAMETERS
9901 LANGUAGE
9902 APPLIC MACRO
AC500 MODBUS
3-WIRE
9903 MOTOR TYPE
9904 MOTOR CTRL MODE
EXIT
00:00
EDIT
Value