Lithium Battery In Monitoring Mode - iCharger 106B+ User Manual

Synchronous balance charger/discharger
Hide thumbs Also See for 106B+:
Table of Contents

Advertisement

iCharger Synchronous Balance Charger/Discharger
Charge-to-discharge & Discharge-to-charge cycle mode for a Lithium battery
LiPo CYCLE
C:4.20V->D:3.00V
-
+
-
Dec
Inc
Dec
-
+
Dec
Inc
Batt type
Start/Enter
stop
>3 seconds
R:03SER S:03SER
CONFIRM(ENTER)
Batt type
Start/Enter
stop
Battery
V-BP
Charge
Li03 1.0A 12.60V
Series
Current
C>D 00993 59m:51
work
cycle
cycle
state
capacity
time
number
cycle
of cells
current
Series

Lithium battery in monitoring mode

When you use other devices to charge or discharge Lithium pack, the iCharger can monitor each cell's
voltage, battery temperature, charge time and so on, if one of the batteries appears over-charged,
over-discharged, over-hot, over-capacity or over-time ,the iCharger will alarm with noise "Di....." and blink
the raleted information.
LiPo MONITOR
3.0V
11.1V(3S)
-
+
-
Dec
Inc
Dec
-
+
Dec
Inc
Batt type
Start/Enter
stop
>3 seconds
Battery
V-BP
Charge
Li03 50℃ 12.60V
Series
Current
Monitor
50m:43
work
run
state
time
number
Ext.
temperature
of cells
Series
Charging/discharging cycle mode of Lithium battery.
3
The left side of the first line sets the type of battery (LiPo, Lilo or LiFe) and
the right side shows the cycle number. The second line shows the cycle
direction you selected: (C: x.xxV->D: x.xxV) or (D: x.xxV->C: x.xxV), the
value of the second line sets the final charge/discharge current. After setting
+
Inc
the current and voltage, press Start/Enter button for more than 3 seconds
with a sound ‖Di‖ to start the next process.
Cycle number: 1 – 10
Voltage: LiPo (3.00 – 4.20V), Lilo (2.50 – 4.10V), LiFe (2.00 – 3.60V)
The number of cells you set and the processor detects. The left side of the
first line 'R: xxSER' shows the number of cells detected by the iCharger
and the right side of the first line 'S:xxSER' is the number of cells set by the
user. If the numbers are different you should make sure that the configured
number and the actual number for the battery are the same and then you
can start charging by pressing Start/Enter. If not, press Batt type/Stop to
go back to the previous screen and adjust the setting.
Charging/discharging cycle mode of Lithium battery.
In this process, you can stop the cycle at any time by pressing the Batt
type/Stop button. In the process of C>D or D>C, the blink ―C‖ indicates
charging, while ―D‖ indicates discharging. Press Inc button to display
each cell's voltage and its past cycling current (see the balance voltage
information& cycling information) and press Dec button to display the
General Status information.
During the waiting time of discharge-to-charge cycle mode, you can stop
battery
the waiting process with pressing ―Start" button for three seconds!
voltage
Monitor mode of Lithium battery. The left side of the first line sets the type of
battery (LiPo, Lilo or LiFe). The value on the right side of the second line
sets the low limit of voltage and the battery pack number. After setting the
current and voltage press Start/Enter button for more than 3 seconds with
+
a sound ‖Di‖ to start the next process.
Inc
Individual alarm low-Vt: final discharging voltage to the highest
charging voltage (such as: LiPo 3.0V – 4.2V),
Battery series: 1 – 6 series
The monitor information, in this process; you can stop monitoring process at
any time by pressing Batt type/Stop button.
Press Inc button to display each cell's voltage (see the balance voltage
information), the iCharger will alarm with noise "Di...."when any errors
appear.
battery
voltage
-18-
106B+

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents