Download Print this page
Edimax WAP1750 Quick Installation Manual
Hide thumbs Also See for WAP1750:

Advertisement

Quick Links

WAP1750
Quick Installation Guide
04-2015 / v1.1

Advertisement

loading

Summary of Contents for Edimax WAP1750

  • Page 1 WAP1750 Quick Installation Guide 04-2015 / v1.1...
  • Page 2: Product Information

    I. Product Information I-1. Package Contents WAP1750 Access Point Quick Installation Guide Antennas x 3 Ethernet Cable Magnetic Wall Mount x 2 Power Adapter & Screws Magnetic Wall Mount Screw Template...
  • Page 3 I-2. System Requirements - Existing cable/DSL modem & router - Computer with web browser for access point configuration I-3. Hardware Overview C LAN 2 E Eject G Reset I On/Off A 12V DC IN D USB Port F Console H WPS B LAN 1 (PoE) 12V DC port to connect the power adapter LAN port with Power over Ethernet (PoE) IN...
  • Page 4 I-4. LED Status LED Status Description The access point is off. Blue The access point is on. Amber The access point is starting up. I-5. Reset If you experience problems with your access point, you can reset the device back to its factory settings. This resets all settings back to default. Press and hold the reset button on the access point for at least 10 seconds than release the button.
  • Page 5: Quick Setup

    II. Quick Setup Your access point can be up and running in just a few minutes. It can function as a standalone access point (AP mode) or as part of an AP array (Managed AP mode or AP Controller mode). This quick installation guide will help to set up your access point and configure its basic settings.
  • Page 6 You will be prompted for a username and password. Enter the default username “admin” and the default password “1234”. You will arrive the “System Information” screen shown below. Please follow the instructions below in II-2. Basic Settings to configure the access point’s basic settings for use as a standalone AP in AP mode.
  • Page 7 For use a Managed AP in an AP array, the access point will automatically switch mode when an AP Controller is configured as described in III. Edimax Pro NMS. To use the AP as an AP Controller (master) in an AP array, refer to III. Edimax Pro NMS. II-2.
  • Page 8 When you change your access point’s IP address, you need to use the new IP address to access the browser based configuration 192.168.2.2. interface instead of the default IP To change the SSID of your access point’s 2.4GHz wireless network(s), go to “Wireless Setting”...
  • Page 9 Go to “Wireless Settings” > “5GHz 11ac 11an” and repeat steps 3 & 4 for the access point’s 5GHz wireless network. To change the administrator name and password for the browser based configuration interface, go to “Management” > “Admin”. Complete the “Administrator Name” and “Administrator Password” fields and click “Apply”.
  • Page 10 Set the correct time and time zone for your access point using the drop down menus. The access point also supports NTP (Network Time Protocol) so alternatively you can enter the host name or IP address of a time server. Click “Apply”...
  • Page 11: Edimax Pro Nms

    Edimax Pro Network Management Suite (NMS) supports the central management of a group of access points, otherwise known as an AP Array. NMS can be installed on one access point and support up to 8 Edimax Pro access points with no additional wireless controller required, reducing costs and facilitating efficient remote AP management.
  • Page 12 Ensure you have the latest firmware from the Edimax website for your Edimax Pro products. Connect all APs to an Ethernet or PoE switch which is connected to a gateway/router. You can use your router as a DHCP server or you can later configure your AP Controller as a DHCP server.
  • Page 13 Designate one AP as the AP Controller which will manage all other connected APs (up to 8). Connect a computer to the designated AP Controller using an Ethernet cable.
  • Page 14 Enter the username & password to login. The default username & password are admin & 1234. You will arrive at the Edimax Pro NMS Dashboard. Go to “Management”  “Operation Mode” and select “AP Controller Mode” from the drop down menu.
  • Page 15 Click “Apply” to save the settings. Edimax Pro NMS includes a wizard to quickly setup the SSID & security for Managed APs. Click “Wizard” in the top right corner to begin. Follow the instructions on-screen to complete Steps 1, 2 & 3 and click...
  • Page 16 Refer to the user manual for help. Your Controller AP & Managed APs should be fully functional. Use the top menu to navigate around Edimax Pro NMS. Use Dashboard, Zone Plan, NMS Monitor & NMS Settings to configure Managed APs.
  • Page 17: Hardware Installation

    IV. Hardware Installation II-1. Router/PoE Switch Connect a router or PoE switch to the access point’s LAN 1 port using an Ethernet cable. PoE switches must be connected to the access point’s LAN 1 port. If you are using a router, then connect the power adapter to the access point’s 12V DC port and plug the power adapter into a power supply.
  • Page 18 COPYRIGHT Copyright  Edimax Technology Co., Ltd. all rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission from Edimax Technology Co., Ltd.
  • Page 19 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 20 EU Declaration of Conformity English: This equipment is in compliance with the essential requirements and other relevant provisions of Directive 1995/5/EC, 2009/125/EC, 2006/95/EC, 2011/65/EC. Français: Cet équipement est conforme aux exigences essentielles et autres dispositions de la directive 1995/5/CE, 2009/125/CE, 2006/95/CE, 2011/65/CE. Čeština: Toto zařízení...
  • Page 21 Declaration of Conformity We, Edimax Technology Co., Ltd., declare under our sole responsibility, that the equipment described below complies with the requirements of the European R&TTE directives. Equipment: AC1750 Wall Mount Access Point Model No.: WAP1750 The following European standards for essential requirements have been followed:...
  • Page 22 Notice According to GNU General Public License Version 2 This product includes software that is subject to the GNU General Public License version 2. The program is free software and distributed without any warranty of the author. We offer, valid for at least three years, to give you, for a charge no more than the costs of physically performing source distribution, a complete machine-readable copy of the corresponding source code.
  • Page 23 1. You may copy and distribute verbatim copies of the Program’s source code as you receive it, in any medium, provided that you conspicuously and appropriately publish on each copy an appropriate copyright notice and disclaimer of warranty; keep intact all the notices that refer to this License and to the absence of any warranty; and give any other recipients of the Program a copy of this License along with the Program.
  • Page 24 5. You are not required to accept this License, since you have not signed it. However, nothing else grants you permission to modify or distribute the Program or its derivative works. These actions are prohibited by law if you do not accept this License. Therefore, by modifying or distributing the Program (or any work based on the Program), you indicate your acceptance of this License to do so, and all its terms and conditions for copying, distributing or modifying the Program or works based on it.

This manual is also suitable for:

Cap1200Cap300