Operation
11. With prime valve horizontal. Trigger gun
into flushing pail to purge fluid from hose.
12. Engage trigger lock.
13. Turn pressure control knob to OFF and
turn ON/OFF switch to OFF position.
Disconnect power to sprayer.
14. Remove filter from gun and sprayer if
installed. Clean and inspect. Install filter.
See separate gun manual.
26
20 s
15. If flushing with water, flush again with
ti24649a
16. Wipe sprayer, hose and gun with a rag
ti24992a
ti24718a
mineral spirits or Pump Armor to leave a
protective coating to prevent freezing or
corrosion.
ti24719a
soaked in water or mineral spirits.
ti24720a
334530D