One Shot Recording (Internal Timer)

As described before, the One Shot Recording is an event
recording function reacting to an alarm input.
It records the number of particular images that have acti-
vated the alarm.
These items let you determine the recording parameters for
One Shot Recording assigned in the program number
menu (continued from Program Timer).
1. Select the recording mode O/S in the program number
menu by pressing the + or - button, then press the
SET button.
The selected One Shot Recording menu as shown
below appears on the monitor screen.
3-1-1-1 PROG1-NO1-G1 REC SETUP
O/S(EVENT RECORDER
REC MODE
REC RATE
QUALITY
PICTURES
2. Move the cursor to the REC RATE parameter in the
menu by pressing the D or C button, then select the
desired recording rate by pressing the + or - button.
1 - 30FPS: Records the selected number of the freeze
image per second.
The factory default setting is 15FPS.
• 30FPS is the active selection when the FIELD/FRAME
parameter in the COMMON REC SETUP menu is set to
FIELD.
• 15FPS is the active selection when the FIELD/FRAME
parameter in the COMMON REC SETUP menu is set to
FIELD or FRAME 3DIM OFF.
3. Move the cursor to the QUALITY parameter by pressing
the D or C button, then select the desired image quali-
ty by pressing the + or - button.
SUPER FINE: For enhanced sharpness (Compression
Rate 1/6)
FINE: For fine image quality (Compression Rate 1/10)
NORMAL: For normal image quality (Compression Rate
1/16)
EXTENDED: For extended time recording quality
(Compression Rate 1/25)
The factory default setting is SUPER FINE.
48
ONE SHOT)
15FPS
SUPER FINE
16
4. Move the cursor to the PICTURE parameter by pressing
the D or C button, then select the number of freeze
images to be recorded by pressing the + or - button.
4 to 60: Records the selected number of freeze images
for One Shot Recording.
The factory default setting is 16.
5. Press the SET UP/ESC button to return to the previous
program number menu.