Set-Up Menu - JVC DT-E15L4 Instructions Manual

Hide thumbs Also See for DT-E15L4:
Table of Contents

Advertisement

Menu Configuration (cont.)

Set-Up Menu

Function Setting
Settings for the sub menu display, color of the tally lamp, and the intensity of the button lamps.
Item
To do
sub menu Position
Select the contents and displaying position of "sub menu."
The setting values and features are as follows.
Lower1
Upper1
Lower2
Upper2
• The adjustment bar is not displayed for some items.
Sync Term
Specify the terminal resistant value of the RGB input synchronized signal from the COMPO./RGB
terminal.
• Normally, select "High". Select "Low" when the display becomes unstable due to the length
Tally Setting
Set the color and mode of the tally lamp using external control.
Tally Type
Normal
Half
Tally Color
Set the tally color when "Tally Type" is set to "Normal".
Dimmer
Select the intensity of the button lamps.
Illumination
Select whether illumination is activated/deactivated.
Component Phase
Deactivates the function of PHASE adjustment (Picture adjustment knob and "Picture Sub
Adjust" in Set-Up Menu) (☞ on page 19) except when an NTSC signal comes in.
Remote Active On
Set the conditions for the power switch by external control (serial).
Standby
On
Off
LCD Saver
Configure the setting for reducing damage to the LCD panel for long-time use. (☞ on page 21)
Setting
1st Start
Set the standby time.
Work
Set the time for performing the function.
Time
Contrast
Set the contrast reduction.
Backlight Reduce the backlight brightness.
OSD
Set the contrast reduction of the OSD display.
Contrast
Side Mask Select whether to use the side panel.
* The Side Mask function works no matter whether the LCD Saver is active or stopped.
reset
Restore the default settings for all the items in "LCD Saver".
Execute
Execute the LCD Saver function.
Cancel
Stop the LCD Saver function. ("Cancel" will be grayed out during the function stop.)
Status
Display the LCD Saver status.
Start After
Stop the LCD Saver function.
Function Key Setting
Specify the function assigned to the F1/F2 button.
Function1
Specify the function assigned to the F1 button.
Function2
Specify the function assigned to the F2 button.
Function Display
Select whether to display the status of the assigned function when you press the F1/F2 button. Off, Mode-1, Mode-2
Off
Mode-1
Mode-2
You can also display "Function Key Setting" Menu by pressing the
Each time you press the F1/F2 button, the setting value for the assigned function changes in order.
Ex: When "Color Temperature" is assigned
Each time you press the button, three setting values alternate.
18
: Displays the current setting and adjustment bar at the lower part of the screen.
: Displays the current setting and adjustment bar at the upper part of the screen.
: Displays the current setting at the lower part of the screen.
: Displays the current setting at the upper part of the screen.
of a connection cable.
:
Light up the entire tally.
:
Light up the left and right halves of the tally individually.
:
Can power on by external control after powered OFF.
:
Cannot power on by external control after powered OFF.
:
No status display. Perform the registration function.
:
Display the status. Perform the registration function.
:
Display the status. Do not perform the registration function.
Perform the registration function when the status is displayed and the button is
pressed again.
See pages 13 to 20 for details of the
functions assigned to Function 1 and
Function 2.
button when the menu is not displayed.
Setting value
Lower1, Upper1, Lower2,
Upper2
Low, High
Normal, Half
Green, Red
Normal, Dark
Off, On
Enable, Disable
Off, On
00h-24h
01h-06h
Save, Normal
Save, Normal
Save, Normal
Off, On
Off, Ready
**h **min
- - -, Aperture, I/P Mode,
Frame, Center Marker,
Level Meter Display,
Gamma,
Color Temperature,
CRC Error, Manual Aspect

Advertisement

Table of Contents
loading

Table of Contents