Specifications; External Outfitting - Noritz N-132 Owner's Manual And Installation Manual

Hide thumbs Also See for N-132:
Table of Contents

Advertisement

Specifications

Specifications
Item
Model Name
Type
Installation
Air Supply/Exhaust
Ignition
Operating Pressure
Minimum Flow Rate
Dimensions
Weight
Water Holding Capacity
Connection Sizes
Water Inlet
Hot Water Outlet
Gas Inlet
Power Supply
Supply
Consumption
Materials
Casing
Flue Collar
Heat Exchanger
Safety Devices
Accessories
Performance table
Item
Gas
NG
Consumption
LP
Hot Water
45˚F Rise
Capacity
72˚F Rise
Capacity Range
Temperature Settings
Default Temperature Options
26
• Specifications may be changed without prior notice.
• The capacity may differ slightly, depending on the water pressure,
water supply, piping conditions, and water temperature.
Specification
N-132
Indoor, Wall Hanging
Power Vented
Direct Ignition
15-150 PSI
0.75 GPM
29.5"(Height) x 18.9"(Width) x 11.8"(Depth)
108 lbs.
0.8 Gallon
1"
1"
3/4"
120 VAC (60Hz)
NG:140W, LP:135W, Freeze Prevention 355W
Zincified Steel Plate/Acryl Coating
Stainless Steel
Copper Sheeting, Copper Tubing
Flame Rod, Thermal Fuse, Pressure Relief Valve,
Wind Pressure Switch, Lightning Protection Device
(ZNR), Electric Leakage Prevention Device, Overheat
Prevention Device, Freezing Prevention Device, Fan
Rotation Detector
Temperature Control Panel, Exhaust Adapter,
Anchoring Screws
Maximum Performance
Minimum Performance
380,000 btuh
20,000 btuh
380,000 btuh
20,000 btuh
13.2 Gal./min.
8.3 Gal./min.
0.75-13.2 Gal./min.
99-118,140,167˚F(14 Options)
108,113,140,167˚F(Original is 108˚F)

External outfitting

022
038
024
050
050
054
034
019
035
021
050
020
055
055
037
013
054
039
017
050
001
007
015
006
052
027
040
033
050
018
023
012
050
013
012
036
029
050
27

Advertisement