TANKLESS GAS WATER HEATER
Owner's Guide
* FOR USE IN RESIDENTIAL OR MANUFACTURED HOME APPLICATIONS.
WARNING
- Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
CERTIFIED
Low NOx Approved
by SCAQMD
14 ng/J or 20 ppm
(Natural Gas Only)
SBB80J3-2
Rev. 01/17
Models : NR98OD (GQ-2857WX US)*
NR98DVC (GQ-2857WX-FFA US)*
NR98SV (GQ-2857WX-F US)
If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury, or death.
Thank you for purchasing this Noritz Tankless Gas Water Heater.
Before using, please:
Read this manual completely for operation instructions.
R
Completely fill out the warranty registration card (included separately)
and mail the detachable portion to Noritz America Corporation.
Keep this manual (and the remainder of the warranty registration card)
where it can be found whenever necessary.
Installation must conform with local codes, or in the absence of local
codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition
and/or the Natural Gas and Propane Installation Code CSA B149.1 -
latest edition.
When applicable, installation must conform with the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280 or the
Canadian Standard CAN/CSA-Z240 MH Mobile Homes, Series M86.
(-OD, -DVC type only)
Noritz America reserves the right to discontinue, or change at any
time, the designs and/or specifications of its products without notice.
NORITZ America Corporation
*SBB80J3*

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GQ-2857WX-FFA US and is the answer not in the manual?

Questions and answers

Summary of Contents for Noritz GQ-2857WX-FFA US

  • Page 1 (Natural Gas Only) Canadian Standard CAN/CSA-Z240 MH Mobile Homes, Series M86. (-OD, -DVC type only) Noritz America reserves the right to discontinue, or change at any time, the designs and/or specifications of its products without notice. NORITZ America Corporation SBB80J3-2 Rev.
  • Page 2: Important Safety Information

    Important Safety Information-1 To prevent damage to property and injury to the user, the icons shown below will be used to warn of varying levels of danger. Every indication is critical to the safe operation of the water heater and must be understood and observed. Potential dangers from accidents during installation and use are divided into the following four categories.
  • Page 3 B. BEFORE OPERATING smell all around the water heater area for If you detect abnormal combustion evidence of leaking gas. Be sure or abnormal odors, or during an to smell next to the floor because earthquake, tornado or fire: some gas is heavier than air and Be sure will settle on the floor. to do. 1. Turn off the hot water supply. 2. Turn off the power to the water heater. WHAT TO DO IF YOU SMELL GAS. 3. Turn off gas and water supply valve. • Do not try to light any 4. Call the nearest Noritz agent. appliance. • Do not touch any electrical switch; do not use any phone Explosion Hazard ; in your building. If the temperature and pressure relief • Immediately call your gas valve is dripping or leaking, have a Prohibited supplier from a neighbor’s qualified service technician replace it. phone. Follow the gas supplier’s Do not plug or remove the valve. instructions. • If you cannot reach your gas Failure to follow these instructions can result supplier, call the fire department.
  • Page 4 Important Safety Information (Continued) WARNING [NR98SV] Do not place the unit or the exhaust vent terminal in an indoor environment by Carbon Monoxide Poisoning Hazard. means of adding walls and ceiling (Do not Do not install this water heater in a mobile Prohibited Prohibited enclose using corrugated sheets, etc.) home, recreational vehicle or on a boat. Exhaust vent terminal [NR98OD, NR98DVC] Carbon Monoxide Poisoning Hazard. Do not install this water heater in a Prohibited Unit recreational vehicle or on a boat. Do not use combustible chemicals such Carbon monoxide poisoning or fire may as oil, gasoline, benzene etc. in the near occur as a result.
  • Page 5 (Continued) [NR98SV] Contact Noritz before using with a solar pre-heater. Check the air supply opening Clogged for dust or obstructions. air supply Be sure Be sure opening!! to do. to do. Do not allow small children to play California Proposition 65 lists chemical substances known to the state to cause cancer, unsupervised in the bathroom. birth defects, death, serious illness or other Do not allow small children to bath Prohibited reproductive harm. This product may contain such unsupervised. substances, be their origin from fuel combustion (gas, oil) or components of the product itself. Do not touch the power cord with wet hands. The gas conversion kit shall be installed by a Don’t touch qualified service agency in accordance with the Electric with a wet Shock.
  • Page 6 Important Safety Information CAUTION Do not drink water that has been inside the This unit is only approved for installation unit for an extended period of time. Do not up to 4500 ft. (1350m) above sea level. drink the first use of hot water from the For installations at higher elevations, contact Noritz unit in the morning. America for Instructions. Clean the filter on the water inlet as Do not disassemble the remote controller. frequently as required by the quality of your local water. ( p.21) Do not use benzene, oil or fat detergents to clean the remote controller. Keep the area around the unit clean. This may cause deformation. If boxes, weeds, cobwebs, cockroaches etc. are in Do not get the remote controller wet. the vicinity of the unit, damage or fire can result.
  • Page 7: Table Of Contents

    Contents Important Safety Information ............... 2 Contents......................7 General Parts Main Unit ....................8 Remote Controller ..................10 Initial Operation .................... 11 How to Use Setting and Using the Water Heater ............12 Flow Meter Alarm ..................14 Muting the Remote Controller ..............16 Adjusting the Maximum Output Temperature ........17 Preventing Damage from Freezing ............. 18 Regular Maintenance ................... 20 Troubleshooting ................... 23 Follow-up Service ..................27 Specifications ....................29...
  • Page 8: General Parts

    General Parts Main Unit NR98OD (GQ-2857WX US) (Outdoor Wall Mounted, Power Vented Model) Exhaust Vent Front Cover Air Inlet Water Drain Valve (with Water Filter) (Inside Water Inlet) p.21) Pressure Relief Valve Water Supply Valve Gas Supply Valve * The above illustration shows an example of installation. The exact installation configuration may be slightly different.
  • Page 9 Main Unit NR98DVC (GQ-2857WX-FFA US) (Indoor Wall Mounted, Power Vent/Sealed Model) Concentric Pipe Front Cover Operation Panel In this Owner’s Guide, this panel will be referred to as Water Drain Valve the “Remote Controller”. (with Water Filter) (Inside Water Inlet) Pressure Relief Valve p.21) Water Supply Valve Gas Supply Valve NR98SV (GQ-2857WX-F US) (Indoor Wall Mounted, Power Vented Model) Flue Collar Front Cover Air Inlet Filter Water Drain Valve (with Water Filter) (Inside Water Inlet) Pressure Relief Valve p.21) Water Supply Valve Gas Supply Valve...
  • Page 10: Remote Controller

    General Parts Remote Controller (RC-7651M) What is actually displayed depends on how the water heater is set. Burner On Indicator Setting Buttons When burning, the For setting the hot indicator is lit. water temperature, ( p.13 and 15) the flow meter alarm, and other settings. Priority Indicator When this indicator is lit, the hot water temperature can be set. p.12) Power On/Off Button Temperature Setting For turning the...
  • Page 11: Initial Operation

    Initial Operation Before the first use of your water heater, do the following: 1 through 4 Follow steps Open the water supply valve. OPEN CLOSED Open a hot water fixture to confirm that water is available, and then close the fixture again. Hot water fixture Open the gas supply valve.
  • Page 12: How To Use

    How to Use Setting and Using the Water Heater (Starting with the Power Off) Press the Power On/Off Button. The temperature will be displayed on the remote control thermostat. Previous set temperature (Ex.: 110°F) DANGER To prevent scalding: High Temperature Hot Water Heater temperatures over 125°F (52°C) can cause severe burns instantly or death from scalding. • Children, disabled and elderly are at the highest risk of being scalded.
  • Page 13 Note : An error code will be displayed when this water heater detects scale build-up in the heat exchanger. The error code may be more frequently displayed when the unit is set to a high temperature. (125°F or higher) Noritz recommends that water temperature is set as low as possible to prevent scale build-up in the heat exchanger.
  • Page 14: Flow Meter Alarm

    How to Use Flow Meter Alarm If the flow meter alarm is being used to indicate when a tub is full: • If any hot water is being used besides what is going into the tub, the alarm will sound before the tub is full. •...
  • Page 15 Water Temperature An alarm will sound for ten °F : The temperatures settings below are only examples. The seconds when the flow temperature setting necessary will depend on the usage, the length of piping and the time of year. reaches the set level. Warm Warmer °C (°F) :...
  • Page 16: Muting The Remote Controller

    How to Use Muting the Remote Controller The remote controller will emit a sound when any button is pushed. This sound can be muted if it is desired. * Initial factory setting is with sound Hold the Power On/Off Button for five seconds. Muted Sound No sound...
  • Page 17: Adjusting The Maximum Output Temperature

    How to Use Adjusting the Maximum Output Temperature Change the Turn off the Press and hold the flow temperature using power. meter alarm set button until the setting buttons. a sound is heard (2 sec.). Tone sounds after 2 sec. Down The upper limit of the hot-water supply temperature can be changed to...
  • Page 18: Preventing Damage From Freezing

    * The freeze prevention heaters will not prevent the plumbing external to the unit from freezing. Protect this plumbing with insulation, heat tape or electric heaters, solenoids, or pipe covers. If there remains a freezing risk, contact the nearest Noritz agent. Take the measures below for extremely cold temperatures*.
  • Page 19 Preventing Damage from Freezing-2 If the water heater will not be used for a long period of time, drain the water. Drain the water as follows: CAUTION To avoid burns, wait until the equipment cools down before draining the water. The appliance will remain hot after it is turned off.
  • Page 20: Regular Maintenance

    Regular Maintenance-1 Periodic Inspection CAUTION To prevent burns or scalding, turn off the power button and wait until the equipment cools before performing maintenance. Be sure to do. For dust and soot in For laundry, newspaper, Check Check the exhaust vent or the timber, oil, spray cans exhaust vent terminal.
  • Page 21 Air Inlet Filter (NR98SV (GQ-2857WX-F US)) CAUTION Do not remove the air inlet filter. If it is removed or damaged, please contact Noritz America. Damage caused by operating the water heater without the air inlet filter is not covered under warranty.
  • Page 22 # = 0, 1, 2, 3, 4, 5, 6, 7, 8, 9 Damage to the water heater as a result of below is not covered by the Noritz America Limited Warranty. To ensure full warranty coverage, treat or condition water that exceeds the target levels provided in this table.
  • Page 23: Troubleshooting

    Troubleshooting-1 Initial Operation • Check for reversed plumbing or crossed pipes. Unit does not attempt to ignite when water is running. • Check the water drain valve filter. ( p.21) Unit attempts to ignite but fails • Reset unit and try again. There may be air in the gas line. •...
  • Page 24 Troubleshooting-2 (Continued) • The unit will not heat the water if the flow rate is less than The water is cold when only a 0.5 gallons (2L) per minute. single fixture is open. Open the fixture more or open other fixtures so that a greater flow passes through the unit, and the unit should begin heating again.
  • Page 25 Remote Controller The light on the power button does • Has there been a power failure? not come on. • Is the power connected properly? The water temperature changes • The temperature setting and the flow meter alarm setting after a power failure or when the may both need to be reset after a power outage.
  • Page 26 If the flashing number doesn't return the problem is solved. [NR981-SV] Clean the air supply vent.( p.21) If the display continues, contact the nearest Noritz The air inlet filter may be clogged. agent. Abnormal combustion, Have a professional check the gas supply pressure.
  • Page 27: Follow-Up Service

    Period of Time for Stocking Repair Parts Noritz will stock repair and maintenance parts for this unit for the time period from the date of the original installation as follows: twelve (12) years for the heat exchanger and ten (10) years for remaining parts.
  • Page 28 This work must be performed by either Noritz or a qualified service agency and will be charged for even during the warranty period. The qualified installer will also be responsible for purchasing the gas conversion kit directly from the manufacturer.
  • Page 29: Specifications

    Specifications-1 • Specifications may be changed without prior notice. • The capacity may differ slightly, depending on the water pressure, water supply, piping conditions, and water temperature. Specifications Item Specification Model Name NR98OD (GQ-2857WX US) Type Installation Outdoor Wall Mounted Air Supply/Exhaust Power Vented Direct Ignition...
  • Page 30 Specifications-2 Specifications Item Specification Model Name NR98DVC (GQ-2857WX-FFA US) Type Installation Indoor Wall Mounted Air Supply/Exhaust Power Vented Ignition Direct Ignition Operating Pressure 15-150 psi Minimum Flow Rate 0.5 GPM (2 L/min.) Dimensions (Height) x (Width) x (Depth) 23.6" (600mm) x 13.8" (350mm) x 11.0" (280mm) Weight 58 lbs.
  • Page 31 • Specifications may be changed without prior notice. • The capacity may differ slightly, depending on the water pressure, water supply, piping conditions, and water temperature. Specifications Item Specification Model Name NR98SV (GQ-2857WX-F US) Type Installation Indoor Wall Mounted Air Supply/Exhaust Power Vented Ignition Direct Ignition...