Cleaning Burner
Caution: Shut off gas/power supply to the unit before proceeding. Wear safety glasses to preform task below.
1. Follow procedure for removing burner assembly, with exception to pulling the burner. The burner does not
have to be removed to clean it.
2. Inspect burner for damage and/or cracks before proceeding.
3. Blow the ceramic burner out using 120 psi of compressed air. Hold the air nozzle back about six inches from
surface during this process. It is recommended the unit be disconnected and moved outside while blowing
out the burner due to the amount of dust created by this process.
4. Reinstall ALL covers and the top panel in the reverse order.
5. Restart unit and check to verify it is operating as designed.