2. Installation method
Before fitting the attachment to the inverter, switch off the power supply and make sure that
the charge lamp has gone out without fail. For details, refer to the "Safety Instructions"
appearing in the manual of the inverter.
2.1. In case of ATFIN7*5
Attachable inverter models
Step 1: Remove the inverter fitting metal (4 pcs) shown in Figure 1 from the inverter.
Step 2: First, fit the top and bottom attachments (Figure 2 [1]) to the inverter, next fit the side
M4×10
[1] Top and bottom attachments
VFA7-2370P1, -2450P1, -2550P1, -4370P1, -4450P1, -4550P1, -4750P1
VFP7-2370P, -2450P, -2550P, -4450P, -4550P, 4750P, -4900P
attachments (Figure 2 [2]) to the inverter with the screws supplied with the
attachment as shown in Figure 2.
(For fitting the bottom attachment, remove the front cover of the inverter
beforehand.)
M4×10
Figure 1
Front cover
M5×12
Figure 2
Among the screws supplied with the attachment,
the following screws remain as unused.
M4X10 screw ... 4 pcs, M5X12 screw ... 3 pcs
-4-
[2] Side attachments
E6581187
M5×12