4. How To Control The Unit
You can operate the unit in three ways:
1. By master/slave built-in preprogram function
2. By DMX controller
There is no need to turn the unit off when you change the DMX address, as new DMX
address setting will be effected at once. Every time you turn the unit on, it will show "
on the display and move all the motors to their 'home' position. After that the unit will be
ready to receive DMX signal or run the built in programs.
4.1 Master/Slave Built In Preprogrammed Function
By linking the units in master/slave connection, the first unit will control the other units to
give an automatic, sound activated, synchronized light show. This function is good when you
want an instant show.
2-light show
In slave mode, Master means the unit runs as the master unit, Slave1 or Slave 2 means
2-light show. In order to create a great light show, you can set Slave1 or Slave 2 on the
second unit to get contrast movement to each other, even if you have two units only.
4.2 DMX Controller
Use universal DMX controller to control the units, you have to set DMX address from 1 to
512 channel so that the units can receive DMX signal.
Press the MENU button up to when
button and the display will blink. Use DOWN and UP button to change the DMX512 address.
Once the address has been selected, press and keep ENTER button pressed up to when
the display stops blinking or storing automatically one minute later. To go back to the
functions without any change press the MENU button again. If you use please refer to the
following diagram to address your DMX512 channel for the first 4 units.
4 channels:
5 channels:
7 channels:
is showing on the display. Pressing ENTER
11-
2. Technical Specifications
Voltage:100-240V~ 50/60Hz
LED: 10W RGBW LED x 22pcs
Fuse: T 6.3A
Power consumption:283W
"
Dimension: 291 x 356 x 413 mm
Weight: 7.8kg
3. How To Set The Fixture
3.1 Control Panel
1 Display: To show the various menus and the selected functions
4-

Advertisement

loading