Electrical Requirements

WARNING
To prevent an electric shock hazard, the power supply
must meet the specifications stated below. It is the own-
er's responsibility to make sure that the electrical service
meets electrical requirements and that the electrical outlet
has been properly installed by a licensed electrician.
The cooktop is supplied with a factory installed,
40-inch, three-prong, grounding electrical cord. It is
connected to the chassis at the bottom right rear corner
(see Chassis Bottom Diagrams below). It must be
connected to a dedicated, grounded three-prong elec-
trical outlet installed by a licensed electrician.
The electrical installation, including minimum supply
wire size and grounding, must be done in accordance
with National Electric Code ANSI/NFPA 70* and local
codes and ordinances. A copy of this standard may be
obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269-9101
The correct voltage, frequency, and amperage must be
supplied to the electrical outlet according to the product
data label located on the bottom of the chassis. See
the Gas and Electrical Requirements table on this
page for reference.
Be certain to position the electrical outlet so that the
power cord may be easily disconnected if the unit
needs service.
Chassis Bottom of RNCT305G
Important Safety Instructions
RNCT365G

Gas Supply Requirements

Be certain that the cooktop being installed is correct
for the gas service being provided (Natural Gas or LP
gas). Also, if using the cooktop at an altitude above
4000 ft. (1219 m) make sure it is equipped for high alti-
tude ("H") operation.
Units equipped for high altitude operation have an "H"
at the end of the model number listed on the product
data label.
Units equipped for LP operation have "LP" in the
model number listed on the product data label. See the
Product Data Label section for label location.
Check your local building codes for the proper method
of installation. In the absence of local codes, this
appliance should be installed in accordance with the
National Fuel Gas Code ANSI Z223.1/NFPA 54.
An external manual shut-off valve must be installed
between the gas supply line and the cooktop for the
purpose of turning on or shutting off gas to the appli-
ance.
The cooktop is shipped from the factory with a regula-
tor in the carton. Use only the regulator provided. The
regulator must be installed between the gas inlet on the
cooktop and the gas shut-off valve.
The regulator inlet accommodates a 3/4" gas line. The
cooktop inlet itself is equipped with a 3/4" male NPT fit-
ting.
See the RNCT305G and RNCT365G image on the left.
RNCT305G_NG
RNCT365G_NG
Gas Type
Natural Gas
Manifold
5" Water
Pressure
column
Min. Gas
6" Water
Supply
column
Pressure **
Max. Gas
Supply
Pressure
Total Connected
0.25 Amp.
Load
(30 Watts)
Circuit
120 Vac,
Requirement
60 Hz, 15 Amp.
Gas and Electrical Requirements*
* The electrical and gas data on this page is for reference
only. If the above data does not agree with the product data
label, use the data on the product data label.
** The gas supply pressure for testing the regulator setting
shall be at least 1-inch water column (249 Pa) above the
specified manifold pressure.
RNCT305G_LP
RNCT365G_LP
LP Gas
10" Water
column
11" Water
column
1/2 psi
1/2 psi
0.25 Amp.
(30 Watts)
120 Vac,
60 Hz, 15 Amp.
3