Symbols; Electromagnetic Declaration - Icare HOME TA022 Instruction Manual

Hide thumbs Also See for Icare HOME TA022:
Table of Contents

Advertisement

Icare HOME tonometer Instruction manual for health care professionals

15. SYMBOLS

Caution
See operating
instructions for more
information
BF-type device
Single-use disposable
SN
Serial number
Use by <date>
Manufacturer
Icare HOME
English
Keep dry
Manufacturing date
Lot number
LOT
Sterilized using irradiation
STERILE R
Stand by
Do not discard this product
with other household-type
waste. Send to appropriate
facility for recovery
and recycling. EU WEEE
(European Union Directive
for Waste of Electronic and
Electrical Equipment)
28
www.icaretonometer.com
Icare HOME tonometer Instruction manual for health care professionals

16. ELECTROMAGNETIC DECLARATION

Icare HOME is class B equipment and needs special precautions regarding EMC and
needs to be installed and put into service according to EMC information provided
below.
Guidance and manufacturer's declaration–Electromagnetic emissions
Icare HOME is intended for use in the electromagnetic environment specified below.
The user of the Icare HOME should assure that it is used in such an environment.
RF emissions CISPR 11
Group 1
Icare HOME is battery operated and use RF energy only for its internal
function. Therefore, its RF emissions are low and are not likely to cause
any interference in nearby equipment.
RF emissions CISPR 11
Class B
Icare HOME is suitable for use in all establishments, including domestic
establishments and those directly connected to public low-voltage power
supply network that supplies buildings used for domestic purposes.
Guidance and manufacturer's declaration–Electromagnetic immunity
Icare HOME is intended for use in the electromagnetic enviroment specified below.
The customers or users of Icare HOME should assure that it is used in such enviroment.
Immunity test
IEC 60601 Test
Compliance
level
level
Electrostatic discharge (ESD) IEC
± 6 kV contact
Complies
61000-4-2
±8 kV air
Power frequency (50/60 Hz)
3 A/m
Complies
magnetic field IEC 61000-4-8
Icare HOME
English
Electromagnetic environment-Guidance
Floors should be wood, concrete or ceramic tile.
If floors are covered with synthetic material, the
relative humidity should be at least 30%.
Power frequency magnetic fields should be at
levels characteristic of a typical location in a
typical commercial or hospital environment.
29